JLG 400S Service And Maintenance Manual page 497

Table of Contents

Advertisement

Help Message
DTC
BOOM ANGLE SENSOR - OUT OF
2344
RANGE HIGH
BOOM ANGLE SENSOR - OUT OF
2345
RANGE LOW
BOOM ANGLE SENSOR – NOT
2346
RESPONDING
FUNCTION PROBLEM - JIB LIFT
2370
UP PERMANENTLY SELECTED
FUNCTION PROBLEM - JIB LIFT
2371
DOWN PERMANENTLY
SELECTED
FUNCTION PROBLEM - SWING
2372
LEFT PERMANENTLY SELECTED
FUNCTION PROBLEM - SWING
2373
RIGHT PERMANENTLY
SELECTED
BOOM ANGLE SENSOR DIS-
2396
AGREEMENT
FUNCTION PROBLEM – TOWER
23105 Machine is in Ground Mode;
LIFT UP PERMANENTLY
SELECTED
FUNCTION PROBLEM – TOWER
23106 Machine is in Ground Mode;
LIFT DOWN PERMANENTLY
SELECTED
FUNCTION PROBLEM - LIFT UP
23107 Machine is in Ground Mode;
PERMANENTLY SELECTED
FUNCTION PROBLEM - LIFT
23108 Machine is in Ground Mode;
DOWN PERMANENTLY
SELECTED
FUNCTION PROBLEM - TELE-
23109 Machine is in Ground Mode;
SCOPE IN PERMANENTLY
SELECTED
3121671
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
The UGM detects that Boom Angle Sensor #1 or Boom
Angle Sensor #2 signal voltage > 4.5V.
The UGM detects that Boom Angle Sensor #1 or Boom
Angle Sensor #2 signal voltage < 0.5V.
The UGM detects the following conditions:
The UGM detects < 1 deg change of Boom Angle
Main Lift Up or Main Lift Down output value ≥ Creep
output value
Main Lift Up or Main Lift Down has been active longer
than 5 seconds.
Machine is in Ground Mode;
MACHINE SETUP > JIB = YES;
The Jib Lift Up switch input = High at Startup
Machine is in Ground Mode;
MACHINE SETUP > JIB = YES;
The Jib Lift Down switch input = High at Startup
Machine is in Ground Mode;
The Swing Left switch input = High at Startup
Machine is in Ground Mode;
The Swing Right switch input = High at Startup
The UGM detects that Boom Angle Sensor #1 and Boom
Angle Sensor #2 readings disagree ≥ 2.5 deg for longer
than 5 seconds;
Do not report if DTC 2343 is active
The Tower Lift Up switch input = High at Startup
The Tower Lift Down switch input = High at Startup
The Lift Up switch input = High at Startup
The Lift Down switch input = High at Startup
The Telescope In switch input = High at Startup
SECTION 6 - JLG CONTROL SYSTEM
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
The UGM shall assume the
Power Cycled
Boom is Above Elevation;
The UGM shall report a
faulted boom angle of 90
degrees
The UGM shall assume the
Power Cycled
Boom is Above Elevation;
The UGM shall report a
faulted boom angle of 90
degrees
The UGM shall assume the
Power Cycled
Boom is Above Elevation;
The UGM shall report a
faulted boom angle of 90
degrees
The UGM shall prohibit Jib
The Jib Lift Up switch input = Low;
Lift Up and Down
Jib Lift Up and Down permitted after con-
trols are initialized
The UGM shall prohibit Jib
The Jib Lift Down switch input = Low;
Lift Up and Down
Jib Lift Up and Down permitted after con-
trols are initialized
The UGM shall prohibit
The Swing Left switch input = Low;
Swing Left and Right
Swing Left and Right permitted after con-
trols are initialized
The UGM shall prohibit
The Swing Left switch input = Low;
Swing Left and Right
Swing Left and Right permitted after con-
trols are initialized
The UGM shall assume the
Power Cycled
Boom is Above Elevation
and will report a faulted
boom angle of 90 degrees
The UGM shall prohibit
The Tower Lift Up switch input = Low;
Tower Lift Up and Down
Tower Lift Up and Down permitted after
controls are initialized
The UGM shall prohibit
The Tower Lift Down switch input = Low;
Tower Lift Up and Down
Tower Lift Up and Down permitted after
controls are initialized
The UGM shall prohibit
The Lift Up switch input = Low;
Lift Up and Down
Lift Up and Down permitted after controls
are initialized
The UGM shall prohibit
The Lift Down switch input = Low;
Lift Up and Down
Lift Up and Down permitted after controls
are initialized
The UGM shall prohibit
The Telescope In switch input = Low;
Telescope In and Out
Telescope In and Out permitted after con-
trols are initialized
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
6-57