JLG 400S Service And Maintenance Manual page 508

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
Help Message
DTC
TELESCOPE OUT VALVE – OPEN
33186 The UGM detects an open circuit at this output
CIRCUIT
TELESCOPE OUT VALVE –
33188 The UGM detects a short to ground at this output
SHORT TO GROUND
TELESCOPE IN VALVE – OPEN
33189 The UGM detects an open circuit at this output
CIRCUIT
TELESCOPE IN VALVE – SHORT
33190 The UGM detects a short to ground at this output
TO GROUND
APU PUMP RELAY - OPEN CIR-
33276 The UGM detects an open circuit at this output
CUIT
APU PUMP RELAY - SHORT TO
33277 The UGM detects a short to battery at this output
BATTERY
APU PUMP RELAY - SHORT TO
33278 The UGM detects a short to ground at this output
GROUND
GLOWPLUG – OPEN CIRCUIT
33279 MACHINE SETUP > ENGINE ≠ DUAL FUEL ECM
GLOWPLUG – SHORT TO BAT-
33280 MACHINE SETUP > ENGINE ≠ DUAL FUEL ECM
TERY
6-68
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
MACHINE SETUP > ENGINE ≠ DEUTZ EMR4
MACHINE SETUP > GLOW PLUG ≠ NO
The UGM detects an open circuit at this output
MACHINE SETUP > ENGINE ≠ DEUTZ EMR4
MACHINE SETUP > GLOW PLUG ≠ NO
The UGM detects a short to battery at this output
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
(340AJ, 400S, 450AJ)
The UGM no longer detects open circuit;
The UGM shall suspend
Full speed Telescope In and Out permitted
Telescope In and Out
after controls are initialized
(18RS, 24RS) The UGM
shall suspend Telescope In
and Out command and
revert to Open Loop Cur-
rent control for Telescope
The UGM shall limit Tele-
scope In and Out to Creep
speed after controls ini-
tialized
The UGM shall prohibit
Power Cycled
Telescope Out;
Tele In speed limited to
Creep
(340AJ, 400S, 450AJ)
The UGM no longer detects open circuit;
The UGM shall suspend
Telescope Out permitted after controls are
Telescope In and Out
initialized;
Full speed Telescope In permitted after con-
(18RS, 24RS) The UGM
trols are initialized
shall suspend Telescope In
and Out command and
revert to Open Loop Cur-
rent control for Telescope
The UGM shall prohibit
Telescope Out;
The UGM shall limit Tele-
scope In to Creep speed
after controls initialized
The UGM shall prohibit
Power Cycled
Telescope In and Out
No response required for
Power Cycled
this DTC
Disable UGM APU Pump
Power Cycled
relay output
Disable UGM APU Pump
Power Cycled
relay output
No response required for
Power Cycled
this DTC
Disable UGM Glow Plug
Power Cycled
relay output
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
3121671