Transport Proximity Switch Installation - JLG 400S Service And Maintenance Manual

Table of Contents

Advertisement

SECTION 4 - BOOM & PLATFORM
SENSOR 2
SEE DETAIL B
SENSOR 1
SEE DETAIL A
DETAIL B
ROTARY ANGLE SENSOR
MUST ACTIVATE WHEN THE BOOM
ANGLE IS AS SPECIFIED BELOW:
DUAL CAPACITY: 51˚±2˚
ABOVE ELEVATION: 5˚±2˚
RESET ABOVE ELEVATION: 3˚±2˚
DETAIL A
1001170642-F
MAF06530
Figure 4-3. Transport Proximity Switch Installation
3121671