JLG 400S Service And Maintenance Manual page 253

Table of Contents

Advertisement

Deutz
Blink
SPN
FMI
Code
Code
523722
8
929
691
523776
9
291
119
523777
9
292
119
523895
13
559
1-5-8
523896
13
560
1-5-8
523897
13
561
1-5-8
523898
13
562
1-5-8
523899
13
563
1-5-8
523900
13
564
1-5-8
3121671
Table 3-16. Deutz Engine Fault Codes
Description
Supply module heater: Faulty PWM signal
from supply module.
Timeout Error of CAN-Receive-Frame
TSC1TE - active
Message TSC1-TE has been missing
(passive)
Missing or wrong injector adjustment
value programming (IMA) injector 1 (in
firing order).
Missing or wrong injector adjustment
value programming (IMA) injector 2 (in
firing order).
Missing or wrong injector adjustment
value programming (IMA) injector 3 (in
firing order).
Missing or wrong injector adjustment
value programming (IMA) injector 4 (in
firing order).
Missing or wrong injector adjustment
value programming (IMA) injector 5 (in
firing order).
Missing or wrong injector adjustment
value programming (IMA) injector 6 (in
firing order).
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
PWM Signal for temperature readout from
sup- ply module to the control unit is not
valid. Supply modul defect, fault in the wiring.
Timeout Error (Missing CAN Bus message)
Passive timeout Error (Missing CAN Bus mes-
sage)
Missing or wrong injector adjustment value
for cyl. 1.
Missing or wrong injector adjustment value
for cyl. 2
Missing or wrong parametrisation of injector
adjustment cyl. 3.
Missing or wrong injector adjustment value
for cyl. 4.
Missing or wrong injector adjustment value
for cyl. 5.
Missing or wrong injector adjustment value
for cyl. 6.
Action
Threshold for error detection is an internal ECU
threshold.
When valid Sync followed by temperature
information signal is received AND valid sync
and temperature signal for both information
is received one after the other.
Supply module check and replace if necessary.
Check the wiring.
Threshold for error detection is an internal ECU
threshold.
Check CAN Bus cabling (Bus scheduling, polar-
ity, short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Check CAN Bus cabling (Bus scheduling,
polarity, short circuit, power interrupt), test
protocol of receiver, check CAN functional
range, check actuator
Threshold for error detection is an internal ECU
threshold.
Check correct injector adjustment value (IMA).
Use SERDIA UseCase to check it.
Threshold for error detection is an internal ECU
threshold.
check dataset and flash correct injector
adjuste- ment value (IMA). Use SERDIA
UseCase to check it.
Threshold for error detection is an internal ECU
threshold.
Check correct injector adjustment value (IMA).
Threshold for error detection is an internal ECU
threshold.
Check correct injector adjustment value (IMA).
Threshold for error detection is an internal ECU
threshold.
Check correct injector adjustment value (IMA).
Threshold for error detection is an internal ECU
threshold.
Check correct injector adjustment value (IMA).
3-195