6.3 RESETTING THE MSSO SYSTEM
1. Use the following procedure to reset the MSSO system.
2. Position the Platform/Ground select switch to the
desired position.
3. Plug the analyzer into the connector coming from the
ground control module or from the platform console.
NOTE: If performing the procedure from the platform console, the
Emergency Stop switch on the ground console must also
be pulled out.
4. Pull out the Emergency Stop switch.
5. The analyzer screen should read:
6. Use the arrow button to reach OPERATOR ACCESS. Press
Enter
.
7. Enter the Access Code, 33271.
8. Use the right Arrow key to reach MENU: CALIBRATIONS.
Press Enter
.
3121671
SECTION 6 - JLG CONTROL SYSTEM
9. Use the arrow keys to reach the LOAD SENSING menu.
The screen should read:
10. Press ENTER
.
11. Use the left arrow key
arrow to reach MSSO RESET.
or right arrow key
6-45