JLG 400S Service And Maintenance Manual page 255

Table of Contents

Advertisement

Deutz
Blink
SPN
FMI
Code
Code
523935
12
168
763
523936
12
169
764
523938
9
133
766
523939
9
134
766
523940
9
135
766
523941
9
140
767
523942
9
141
767
523943
9
142
767
3121671
Table 3-16. Deutz Engine Fault Codes
Description
Timeout Error of CAN-Transmit-Frame
EEC3VOL1; Engine send messages
Timeout Error of CAN-Transmit-Frame
EEC3VOL2; Engine send messages
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1IGCVol1 information;
factors & Sensor calibration for NOX Sensor
(SCR-system upstream cat; DPF-system
downstream cat).
Broadcast Announce Message of the
calibra- tion message
of the upstream catalytic NOx sensor has
failed.
Timeout Error (BAM to BAM) for CAN-
Receive-Frame AT1IGCVol1 information.
factors & Sensor calibration for NOX Sensor
(SCR-system upstream cat, DPF-system
downstream cat).
Timeout Error (PCK2PCK) for CAN-Receive-
Frame AT1IGCVol1 information; factors &
Sensor calibration for NOX Sensor (SCR-sys-
tem upstream cat; DPF-system
downstream cat).
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1OGCVol2 information;
factors & Sensor calibration for NOX Sensor
(SCR-system downstream cat; DPF-system
downstream cat)
Timeout Error (BAM to BAM) for CAN-
Receive-Frame AT1OGCVol2 information,
Calibration message 1 of the after catalyst
NO sensor has failed.
Factors & Sensor calibration for NOX Sensor
(SCR-system downstream cat, DPF-system
downstream cat)
Timeout Error (PCK2PCK) for CAN-Receive-
Frame AT1OGCVol2 information; factors &
Sensor calibration for NOX Sensor (SCR-sys-
tem downstream cat; DPF-system
downstream cat)
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
Fault is detected if a TimeOut of the EEC3VOL1
frame has occured.
Timeout Error (Missing CAN Bus message)
Failure of the CAN Bus message
Defective Nox sensor, faulty parameterization NOX sensor and sensor connection check
Failure of the CAN Bus message
Timeout Error (Missing CAN Bus message)
Defective Nox sensor, faulty parameterization. NOX downstream sensor and sensor
The fault is detected when a timeout error in
packet 2 of NOxSenVol2Rx frame occurs.
Action
Check wiring harness and customer nodes
Check wiring harness and customer nodes
NOX sensor and sensor connection check
NOX sensor and sensor connection check
NOX downstream sensor and sensor
connection check
connection check.
NOX downstream sensor and sensor
connection check
3-197

Advertisement

Table of Contents
loading

This manual is also suitable for:

460sj

Table of Contents