Deutz
Blink
SPN
FMI
Code
Code
523550
12
980
515
523601
13
948
282
523612
3
644
555
523612
4
646
555
523612
12
387
555
523612
12
612
555
523612
12
613
555
523612
12
614
555
523612
12
615
555
3121671
Table 3-16. Deutz Engine Fault Codes
Description
Terminal 50 was operated for more than 2
minutes. This may happen due to short to
battery or wrong usage of Terminal 50.
Starter control is disabled until this error is
healed.
Internal hardware monitoring: the ECU
detects a deviation of the target range of
the power supply voltage of sensor output
3.
supply voltage too high
supply voltage too low
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged
internally; no item will be created in error
memory
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged
internally; no item will be created in error
memory.
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged
internally; no item will be created in error
memory
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged
internally;
no item will be created in error memory
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged
internally;
no item will be created in error memory
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
Start information to Starter (T50-switch)
erratic/defect.
Suspected components EDC17cv52
Pin A18: DeltaPressVenturi / Position intake
throttle flap
Pin K20: First footpedal
Pin K21: Air FilterDiffPress
Suspected components EDC17cv54 and cv56
Pin A07: Rail pressure
not used
not used
Injector shut off demand for the ICO
coordinator
System responses:
not
Plausibility check failed (MoCADC_uNTP_mp
is higher than MoCADC_uNTPMax_C).
Analysis of test voltage (Value is out of the tar-
get -> ECU internal error)
Analysis of the ratio metric correction (Value is
out of the target -> ECU internal error)
Error report due to an error in the plausibility
of Function Coordination(FC) and
Monitoring Modul(MM)(ECU internal error)
Action
Threshold for error detection is an internal ECU
threshold.
Check cabling, if sensor not working, check
start switch and if necessary replace it,
check connection cable and if necessary repair
or replace it.
Check cabling of external components, check
working voltage and if necessary correct
it,
check connection cable and if necessary repair
or replace it,
if error is not removable, change ECU.
Threshold for error detection is an internal ECU
threshold.
Threshold for error detection is an internal ECU
threshold.
Threshold for error detection is an internal ECU
threshold.
Caution! Sequence error, check error memory
for other errors.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
Check wiring, check connected sensors
actuators.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
Check wiring, check connected sensors
actuators.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
3-187