Diagnostic Menu

The Diagnostic Menu is another troubleshooting tool for the
Load Sensing System. Sensor and status information is pre-
sented in real-time for the technician. Several sub-menus exist
to organize the data.
To access the Diagnostic Menu, use the LEFT
Arrow keys to select DIAGNOSTICS from the Top Level
Menu. Press the ENTER key
Diagnostics Menu
st
(Displayed on Analyzer 1
Line)
PLATFORM LOAD
PLATFORM LOAD
PLATFORM LOAD (service*)
PLATFORM LOAD (service*)
PLATFORM LOAD (service*)
PLATFORM LOAD (service*)
PLATFORM LOAD (service*)
PLATFORM LOAD (service*)
PLATFORM LOAD (service*)
PLATFORM LOAD (service*)
* Indicates only visible in service view mode
** Typically indicates a DTC is active
3121671
and RIGHT
to view the menu.
Table 6-5. Diagnostic Menu Descriptions
Parameter (Displayed on
nd
Analyzer 2
Line)
(Displayed on Analyzer 2
STATE:
OK / OVERLOAD
ACTUAL:
XXX.X KG
GROSS:
XXX.X KG
OFFSET 1:
XXX.X KG
OFFSET 2:
XXX.X KG
ACCESSORY
XXX.X KG
UNRESTRICT
XXX.X KG
RESTRICT
XXX.X KG
RAW 1:
XXX.X KG
RAW 2:
XXX.X KG
SECTION 6 - JLG CONTROL SYSTEM
Press the LEFT and RIGHT Arrow keys to view the displays and
select the various sub-menus. To access a sub-menu, press the
ENTER key. Once in a sub-menu, press the LEFT and RIGHT
Arrow keys to view the various displays (just like a Top Level
menu). To exit a sub-menu, press the ESC key
Table 6-5, Diagnostic Menu Descriptions details the structure
of the Diagnostic Menu, and describes the meaning of each
piece of information presented.
Parameter Value
nd
Line)
LSS Status.
Calibrated weight of the platform.
??? if Platform Load is Unhealthy**.
Gross weight of the platform.
??? if both Cells are Unhealthy**.
Stored offset weight of Cell 1.
??? if LSS is not calibrated.
Stored offset weight of Cell 1.
??? if LSS is not calibrated.
Stored accessory weight.
??? if LSS is not calibrated.
UGM will set Unrestricted Rated Load as defined by Machine Con-
figuration.
UGM will set Restricted Rated Load as defined by Machine Config-
uration.
Gross value from Cell 1.
??? if Unhealthy**.
Gross value from Cell 2.
??? if Unhealthy**.
.
Description
6-37