JLG 400S Service And Maintenance Manual page 227

Table of Contents

Advertisement

Deutz
Blink
SPN
FMI
Code
Code
729
5
545
263
729
12
547
263
898
9
305
118
1079
13
946
282
1080
13
947
282
3121671
Table 3-16. Deutz Engine Fault Codes
Description
The cold start aid relay is according to
wiring faulty.
The cold start aid relay is overheated,
which causes this error
Timeout Error of CAN-Receive-Frame
TSC1TE
- active
Internal hardware monitoring: the ECU
detects a deviation of the target range of
the power supply voltage of sensor output
1.
Internal hardware monitoring: the ECU
detects a deviation of the target range of
the power supply voltage of sensor output
2.
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
Relay defect or wire harness problem
High temperature around the cold start relay. Check the functionality of relay and replace it
Timeout Error (Missing CAN Bus message)
Suspected components EDC17cv52
Pin A19: DEF press / Exh.PressBeforeTurb (P3)
/ Air Pump Press
/BrnFuelPressAfterDV2 Pin K19: Fan Speed
Sensor
Pin A21: LDF6T / OilPress / LowFuel Press Pin
A17: Rail Pressure Sensor
Suspected components EDC17cv54
Pin A21: CAM speed Pin K44: Delta Press
Venturi
/ Poti EGR or Inlet Throttle
Pin A24: LDF6T / OilPress / LowFuelPressPin
K43: Reserve 5V Sensor Supply Pin A09:
second footpedal Suspected components
EDC17cv56
Pin A21: Cam speed Pin K44: DEF press / Air
Fil-
terDiffPress
Pin A24: LDF6T / OilPress / LowFuelPress Pin
K43: second footpedal
Pin A09: Delta Press Venturi
Suspected components EDC17cv52
Pin K16: second footpedal
Pin A20: Exh.PressAfterTurb/DPFDiffPress/
BrnDV1Press/HCIPressDV1DV2
Suspected components EDC17cv54
Pin K45: DPF Diff Press / Exh. Press After Turb /
Fan Speed Sensor
Pin A46: first footpedal
Suspected components EDC17cv56
Pin A22: Fan Speed Sensor
Pin K45: Position EGR or Intake throttle flap
Pin K46: First footpedal
Action
Threshold for error detection is an internal ECU
threshold.
Electrical error, check wires
if needed.
Check the temperature around the cold start
relay during worst case operation.
Check CAN Bus cabling (Bus scheduling, polar-
ity, short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Check cabling of external components, check
working voltage and if necessary correct
it,
check connection cable and if necessary repair
or replace it,
if error is not removable, change ECU.
Check cabling of external components, check
working voltage and if necessary correct
it, check connection cable and if necessary
repair or replace it, if error is not removable,
change ECU.
3-169