SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
5232719
3
1108
672
3-214
Table 3-16. Deutz Engine Fault Codes
Description
Urea supply module heater: the current
drain measured by ECU is above the target
range
Possible Cause
Short circuit to battery
If this error detected during the heating phase
it is a result error: KWP 1089
Broken wiring
Heating element in supply module defect
Action
Threshold for error detection is an internal ECU
threshold
Check wiring
Check cabling, if necessary replace supply
module
3121671