JLG 400S Service And Maintenance Manual page 527

Table of Contents

Advertisement

Help Message
DTC
MACHINE SAFETY SYSTEM
873
OVERRIDE OCCURRED
LSS WATCHDOG RESET
991
LSS EEPROM ERROR
992
LSS INTERNAL ERROR – PIN
993
EXCITATION
LSS INTERNAL ERROR – DRDY
994
MISSING FROM A/D
EEPROM FAILURE - CHECK ALL
998
SETTINGS
FUNCTIONS LOCKED OUT -
9910
PLATFORM MODULE SOFT-
WARE VERSION IMPROPER
FUNCTION LOCKED OUT - LSS
9911
MODULE SOFTWARE VERSION
IMPROPER
CHASSIS TILT SENSOR NOT GAIN
9915
CALIBRATED
PLATFORM SENSOR REF VOLT-
9920
AGE OUT OF RANGE
3121671
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
MSSO = Active
MACHINE SETUP > LOAD SYSTEM ≠ NO;
Load System is the 4-Cell LSS;
UGM detects LSS report of an anomaly exists that has
caused a WatchDog Timer reset.
MACHINE SETUP > LOAD SYSTEM ≠ NO;
Load System is the 4-Cell LSS;
UGM detects LSS report of an anomaly that exists in the
LSS EEPROM
MACHINE SETUP > LOAD SYSTEM ≠ NO;
Load System is the 4-Cell LSS;
UGM detects LSS report of improper excitation voltage
MACHINE SETUP > LOAD SYSTEM ≠ NO;
Load System is the 4-Cell LSS;
UGM detects LSS report of an anomaly that exists in the
LSS A/D converter operations.
The UGM has detected an anomaly in EEPROM
The UGM software version type is 'P' or 'B'
The UGM has received valid version information from
the PM
The PM software version type is 'P' or 'B'
The UGM software major version number does not
match the major version number of the platform soft-
ware
MACHINE SETUP > LOAD SYSTEM ≠ NO;
Load System is the 4-Cell LSS;
The UGM determines that the LSS software version is
not compatible with existing code.
The tilt sensor gain calibration values recorded to flash
memory during Phoenix International' s manufactur-
ing test are not present
The PM detects that its reference voltage is out of range
and reports the fault to the UGM
SECTION 6 - JLG CONTROL SYSTEM
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
Response described in
Fault shall be retentive through Power
MSSO Influence on
Cycled;
Machine Operation sec-
Can be reset only with an Analyzer via the
tion
CALIBRATIONS > MSSO > MSSO RESET
menu
UGM to set Platform Load
Power Cycled
State = Overloaded
UGM to set Platform Load
Power Cycled
State = Overloaded
UGM to set Platform Load
Power Cycled
State = Overloaded
UGM to set Platform Load
Power Cycled
State = Overloaded
Disable all machine and
Power Cycled
engine functions (i.e.,
command engine shut-
down and do not permit
start); reset the section of
EEPROM where the failure
occurred to defaults.
Activate the platform
Not all of the trigger conditions are met
alarm continuously
Creep mode is active
If Platform Mode is active,
disable all Drive, Steer,
and Boom functions and
do not permit Machine
Enable
UGM to set Platform Load
Power Cycled
State = Overloaded
The UGM reports a faulted
Valid values are present
chassis tilt angle of 90
degrees
If in Platform mode, Lift/
Power Cycled
Swing and Drive shall be
place in Creep. All other
functions shall operate
normally.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
6-87