SECTION 6 - JLG CONTROL SYSTEM
Help Message
DTC
FUNCTION PROBLEM - TELE-
23110 Machine is in Ground Mode;
SCOPE OUT PERMANENTLY
SELECTED
FUNCTION PROBLEM - PLAT-
23111 Machine is in Ground Mode;
FORM LEVEL UP PERMANENTLY
SELECTED
FUNCTION PROBLEM - PLAT-
23112 Machine is in Ground Mode;
FORM LEVEL DOWN PERMA-
NENTLY SELECTED
FUNCTION PROBLEM - PLAT-
23113 Machine is in Ground Mode;
FORM ROTATE LEFT PERMA-
NENTLY SELECTED
FUNCTION PROBLEM - PLAT-
23114 Machine is in Ground Mode;
FORM ROTATE RIGHT PERMA-
NENTLY SELECTED
TELESCOPE RETRACT
23154 The UGM detects the following conditions:
SWITCHES - DISAGREEMENT
SWING SWITCHES - DISAGREE-
23155 The UGM detects the following conditions:
MENT
FUNCTION PROBLEM – MSSO
23163 The MSSO switch input = Low at Startup
PERMANENTLY SELECTED
BOOM ANGLE SENSOR - SINGLE
23170 Single point Boom Angle calibration is successfully
POINT CALIBRATION PER-
FORMED
CAPACITY LENGTH SWITCHES -
23173 Dual Capacity is configured;
DISAGREEMENT
6-58
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
The Telescope Out switch input = High at Startup
The Platform Level Up switch input = High at Startup
The Platform Level Down switch input = High at
Startup
The Platform Rotate Left switch input = High at Startup
The Platform Rotate Right switch input = High at
Startup
Telescope Retracted Switch #1 and Telescope Retracted
Switch #2 readings disagree for longer than 5 seconds;
Telescope In or Telescope Out output value ≥ Creep out-
put value
Swing Switch #1 and Swing Switch #2 readings dis-
agree for longer than 5 seconds;
Swing Left or Swing Right value ≥ Creep output value
completed
The UGM detects the following conditions:
Capacity Length Switch #1 and Capacity Length Switch
#2 readings disagree for longer than 5 seconds;
Telescope In or Telescope Out output value ≥ Creep out-
put value
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
The UGM shall prohibit
The Telescope Out switch input = Low;
Telescope In and Out
Telescope In and Out permitted after con-
trols are initialized
The UGM shall prohibit
The Platform Level Up switch input = Low;
Platform Level Up and
Platform Level Up and Down permitted
Down
after controls are initialized
The UGM shall prohibit
The Platform Level Down switch input =
Platform Level Up and
Low;
Down
Platform Level Up and Down permitted
after controls are initialized
The UGM shall prohibit
The Platform Rotate Left switch input =
Platform Rotate Left and
Low;
Right
Platform Rotate Left and Right permitted
after controls are initialized
The UGM shall prohibit
The Platform Rotate Right switch input =
Platform Rotate Left and
Low;
Right
Platform Rotate Left and Right permitted
after controls are initialized
The UGM shall assume the
Power Cycled
Boom is Not Retracted
The UGM shall assume the
Power Cycled
Boom is Swung
No response required for
Power Cycled
this DTC
No response required for
Fault shall be retentive through Power
this DTC
Cycled;
Can be reset if CALIBRATIONS > BOOM
ANGLE is successfully completed
The UGM shall assume
Power Cycled
Dual Capacity = 600#
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
3121671