SECTION 6 - JLG CONTROL SYSTEM
FUNCTION
DRIVE
Drive to Stop
MT: Elevated
ME: Elevated
Max Torque
Mid Engine
ME = Max Engine, MT = Max Torque
SWING
LEFT
RIGHT
LIFT
UP
DOWN
TELECOPE
IN
OUT
6-50
Table 6-10. Machine Model Adjustment Speeds
ADJUSTMENT RANGES
Accel
25 – 2000mA/s
Decel
25 – 2000mA/s
Min
250 – 1000mA
Max
250 – 1400mA
Decel
25 – 2000mA/s
Max
250 – 1200mA
Max
250 – 1200mA
Creep
250 – 1200mA
Creep
250 – 1200mA
Accel
0 – 5s
Decel
0 – 5s
Min
250 – 1400mA
Max
250 – 1400mA
Creep
250 – 1400mA
Min
250 – 1400mA
Max
250 – 1400mA
Creep
250 – 1400mA
Accel
0 – 5s
Decel
0 – 5s
Min
250 – 1400mA
Max
250 – 1400mA
Creep
250 – 1400mA
Min
250 – 1400mA
Max
250 – 1400mA
Creep
250 – 1400mA
Soft Down
250 – 1400mA
Soft Down
250 – 1400mA
Accel
0 – 5s
Decel
0 – 5s
Min
250 – 1400mA
Max
250 – 1400mA
Creep
250 – 1400mA
Min
250 – 1400mA
Max
250 – 1400mA
Creep
250 – 1400mA
400S / 460SJ
MODEL
DEFAULTS
300mA/s
800 mA/s
725 mA
1175 mA
30 – 34
400 mA/s
890 mA
795 mA
68 – 85
990 mA
835mA
68 – 85
890 mA
795 mA
990 mA
835mA
2.2 s
1.2s
420 mA
860 mA
70 – 90
650 mA
400 mA
800 mA
70 – 90
650 mA
1.5 s
0.8 s
400 mA
900 mA
33 – 40
600 mA
380 mA
750 mA
33 – 40
500 mA
450 mA
450 mA
1 s
0.8 s
415 mA
890 mA
33 – 40
580 mA
415 mA
780 mA
33 – 40
525 mA
MODEL TIME RANGES
(IN SECONDS)
400S
460SJ
30 – 34
68 – 85
68 – 85
70 – 90
70 – 90
34 – 41
34 – 41
33 – 40
33 – 40
3121671