SECTION 6 - JLG CONTROL SYSTEM
Table 6-2. Machine Configuration Programming Information (Software Version P2.10)
Configuration
Number
Label/Digit
STARTER LOCKOUT:
1
6*
2
* Only visible for Engine Selection = Kubota D1105, Deutz EMR2 or Deutz EMR4.
ENGINE SHUTDOWN:
1
7
2
FUEL CUTOUT:
1
8*
2
3
4
*Only visible for Engine Selection = Kubota D1105, Deutz EMR2 or Deutz EMR4.
* Only visible if Fuel Level Menu selection is not NONE.
6-20
DISABLED: Automatic pre-glow time determined by ambient air temperature; engine start can be
attempted at any time during pre-glow.
ENABLED: Automatic pre-glow time determined by ambient air temperature; engine start is NOT permitted until pre-
glow is finished.
DISABLED: No engine shutdown.
ENABLED: Shutdown engine for high coolant temperature fault or low oil pressure fault.
ONE RESTART: One restart with limited run time when near Empty.
ENGINE STOP: No starting permitted when near Empty.
NONE
RESTART: Restarts allowed with limited run time when near Empty.
Description
Default
Number