SECTION 6 - JLG CONTROL SYSTEM
Help Message
DTC
DRIVE LOCKED - JOYSTICK
2212
MOVED BEFORE FOOTSWITCH
STEER LOCKED - SELECTED
2213
BEFORE FOOTSWITCH
D/S JOY. OUT OF RANGE HIGH
2216
D/S JOY. CENTER TAP BAD
2217
L/S JOY. OUT OF RANGE HIGH
2219
L/S JOY. CENTER TAP BAD
2220
LIFT/SWING LOCKED - JOY-
2221
STICK MOVED BEFORE FOOT-
SWITCH
WAITING FOR FSW TO BE OPEN
2222
6-54
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
Machine is in Platform Mode;
The UGM detects one of the following conditions:
Drive joystick is not in the neutral position at Startup;
Drive joystick is not in the neutral position when Foot-
switch becomes active or while DTC 2213, 2221 or 2223
is active
Machine is in Platform Mode;
A Steer input is active when Footswitch becomes active
or while DTC 2212, 2221 or 2223 is active
The PM detects that the Drive or Steer joystick signal
voltage > 8.1V and reports the fault to the UGM.
The PM detects that the Drive or Steer center tap volt-
age is not between 3.31 volts and 3.75 volts and reports
the fault to the UGM
The PM detects that the Lift or Swing joystick signal
voltage > 8.1V and reports the fault to the UGM.
The PM detects that the Lift or Swing center tap voltage
is not between 3.31 volts and 3.75 volts and reports the
fault to the UGM
Machine is in Platform Mode;
The UGM detects one of the following conditions:
Lift and/or Swing joystick is not in the neutral position
at Startup;
Lift and/or Swing joystick is not in the neutral position
when Footswitch becomes active or while DTC 2212,
2213 or 2223 is active
Machine is in Platform Mode;
Footswitch is active at Start Up
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
If triggered by the Drive
If triggered by the Drive joystick not being in
joystick not being in the
the neutral position at Startup, then (Drive
neutral position at
joystick is returned to its neutral position)
Startup, the UGM shall
and (Drive and Steer permitted after con-
prohibit Drive and Steer.
trols initialized)
If triggered by the Drive
If triggered by the Drive joystick not being in
joystick not being in the
the neutral position when Footswitch
neutral position when
becomes active or while DTC 2213, 2221 or
Footswitch becomes
2223, then controls initialized
active or while DTC 2213,
2221 or 2223 is active, the
UGM shall not Enable the
Machine
The UGM shall not Enable
Controls initialized
the Machine
The UGM shall prohibit
The PM no longer reports the fault
Drive;
Brake release and Steer
still permitted
The UGM shall prohibit
The PM detects that the drive/steer center
Drive;
tap voltage is between 3.31 and 3.75 volts
Brake release and Steer
and no longer reports the fault to the UGM
still permitted
If the Machine is in Plat-
The PM detects that the Lift and Swing joy-
form Mode, the UGM shall
stick signal voltage is < 8.1V and no longer
prohibit Lift and Swing
reports the fault to the UGM
If the Machine is in Plat-
The PM detects that the lift/swing center
form Mode, the UGM shall
tap voltage is between 3.31 and 3.75 volts
prohibit Lift and Swing
and no longer reports the fault to the UGM
If triggered by the Lift
If triggered by the Lift and/or Swing joystick
and/or Swing joystick not
not being in the neutral position at Startup,
being in the neutral posi-
then (Lift and/or Swing joystick is returned
tion at Startup, the UGM
to its neutral position) and (Lift and Swing
shall prohibit Lift and
permitted after controls initialized)
Swing.
If triggered by the Lift and/or Swing joystick
If triggered by Lift and/or
is not in the neutral position when Foot-
Swing joystick is not in the
switch becomes active or while DTC 2212,
neutral position when
2213 or 2223 is active, then controls initial-
Footswitch becomes
ized
active or while DTC 2212,
2213 or 2223 is active, the
UGM shall not Enable the
Machine
The UGM shall not Enable
Controls initialized
the Machine
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
3121671