JLG 400S Service And Maintenance Manual page 515

Table of Contents

Advertisement

Help Message
DTC
JIB LIFT UP VALVE – OPEN CIR-
3415
CUIT
JIB LIFT UP VALVE – SHORT TO
3416
BATTERY
JIB LIFT UP VALVE – SHORT TO
3417
GROUND
JIB LIFT DOWN VALVE – OPEN
3418
CIRCUIT
JIB LIFT DOWN VALVE – SHORT
3419
TO BATTERY
JIB LIFT DOWN VALVE – SHORT
3420
TO GROUND
FUEL SENSOR - SHORT TO BAT-
431
TERY OR OPEN CIRCUIT
FUEL SENSOR - SHORT TO
432
GROUND
ENGINE TROUBLE CODE
437
3121671
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
MACHINE SETUP > JIB = YES
The PM detects an open circuit at this output and
reports it to the UGM
MACHINE SETUP > JIB = YES
The PM detects a short to battery at this output and
reports it to the UGM
MACHINE SETUP > JIB = YES
The PM detects a short to ground at this output and
reports it to the UGM
MACHINE SETUP > JIB = YES
The PM detects an open circuit at this output and
reports it to the UGM
MACHINE SETUP > JIB = YES
The PM detects a short to battery at this output and
reports it to the UGM
MACHINE SETUP > JIB = YES
The PM detects a short to ground at this output and
reports it to the UGM; detection occurs for PWM output
approximately ≤ 15% or for STG condition.
UGM fuel sensor analog input J2-25 detects a voltage
higher than 2.50 volts (A/D > 512)
UGM fuel sensor analog input J2-25 detects a voltage
less than or equal to 0.3 volts (A/D < 61)
An engine with a CAN engine controller is configured in
MACHINE SETUP
The engine controller reports a J1939 fault
SECTION 6 - JLG CONTROL SYSTEM
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
The UGM shall suspend
The PM no longer detects open circuit;
commands to PM for Jib
Full speed Jib Lift Up and Down permitted
Lift Up and Down;
after controls are initialized
The UGM shall limit Jib Lift
Up and Down to Creep
speed
The UGM shall disable
Power Cycled
commands to PM for Jib
Lift Up and Down;
The UGM shall prohibit
Flow Control
The UGM shall disable
Power Cycled
commands to PM for Jib
Lift Up;
The UGM limits Jib Lift
Down to Creep speed
The UGM shall suspend
The PM no longer detects open circuit;
commands to PM for Jib
Jib Lift Up permitted after controls are ini-
Lift Up and Down;
tialized
The UGM shall prohibit Jib
Full speed Jib Lift Down permitted after
Lift Up;
controls are initialized
The UGM shall limit Jib Lift
Down to Creep speed
The UGM shall disable
Power Cycled
commands to PM for Jib
Lift Up and Down;
(450AJ) The UGM shall
prohibit Flow Control
The UGM shall disable
Power Cycled
commands to PM for Jib
Lift Up and Down
Energize fuel sensor per
Power Cycled
System Indicators
Energize fuel sensor per
Power Cycled
System Indicators
Report and log in Help
Power Cycled
If [(MACHINE SETUP >
DEUTZ EMR2) or
(MACHINE SETUP >
DEUTZ EMR4) and
SPN:FMI = 535:7], pro-
hibit engine cranking
X
X
X
X
X
X
X
X
X
X
6-75

Advertisement

Table of Contents
loading

This manual is also suitable for:

460sj

Table of Contents