JLG 400S Service And Maintenance Manual page 506

Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
Help Message
DTC
PLATFORM ROTATE RIGHT
3398
VALVE – OPEN CIRCUIT
PLATFORM ROTATE RIGHT
3399
VALVE – SHORT TO BATTERY
JIB LIFT UP VALVE - SHORT TO
33100 MACHINE SETUP > JIB = YES;
GROUND
JIB LIFT UP VALVE - OPEN CIR-
33101 MACHINE SETUP > JIB = YES;
CUIT
JIB LIFT UP VALVE - SHORT TO
33102 MACHINE SETUP > JIB = YES;
BATTERY
JIB LIFT DOWN VALVE - SHORT
33103 MACHINE SETUP > JIB = YES;
TO GROUND
JIB LIFT DOWN VALVE - OPEN
33104 MACHINE SETUP > JIB = YES;
CIRCUIT
JIB LIFT DOWN VALVE - SHORT
33105 MACHINE SETUP > JIB = YES;
TO BATTERY
TOWER LIFT UP VALVE – SHORT
33106 The UGM detects a short to ground at this output
TO GROUND
6-66
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
The UGM detects an open circuit at this output
The UGM detects a short to battery at this output
The UGM detects a short to ground at this output
The UGM detects an open circuit at this output
The UGM detects a short to battery at this output
The UGM detects a short to ground at this output
The UGM detects an open circuit at this output
The UGM detects a short to battery at this output
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
The UGM shall suspend
The UGM no longer detects open circuit;
Platform Rotate Left and
(340AJ, 400S, 450AJ) Full speed Platform
Right;
Rotate Left and Right permitted after con-
(340AJ, 400S, 450AJ) The
trols are initialized
UGM shall limit Platform
Rotate Left and Right to
Creep speed after controls
initialized;
(18RS, 24RS) Platform
Rotate Left and Right per-
mitted after controls are
initialized
The UGM shall prohibit
Power Cycled
Platform Rotate Left,
Right and Flow Control
Valve outputs
The UGM shall prohibit Jib
Power Cycled
Lift Up;
The UGM shall limit Jib Lift
Down to Creep speed
The UGM shall suspend Jib
The UGM no longer detects open circuit;
Lift Up and Down;
Full speed Jib Lift Up and Down permitted
The UGM shall limit Jib Lift
after controls are initialized
Up and Down to Creep
speed after controls ini-
tialized
The UGM shall prohibit Jib
Power Cycled
Lift Up, Down and Flow
Control
The UGM shall prohibit Jib
Power Cycled
Lift Up and Down
The UGM shall suspend Jib
The UGM no longer detects open circuit;
Lift Up and Down;
Jib Lift Up permitted after controls are ini-
The UGM shall prohibit Jib
tialized
Lift Up;
Full speed Jib Lift Down permitted after
The UGM shall limit Jib Lift
controls are initialized
Down to Creep speed after
controls initialized
The UGM shall prohibit Jib
Power Cycled
Lift Up, Down and Flow
Control
The UGM shall prohibit
Power Cycled
Tower Lift Up;
The UGM shall limit Tower
Lift Down Creep speed
X
X
X
X
X
X
X
X
X
3121671

Advertisement

Table of Contents
loading

This manual is also suitable for:

460sj

Table of Contents