Test Notes; Torque Requirements; Lubrication; Deutz F4M1011F Engine - JLG 600SJC Service And Maintenance Manual

Table of Contents

Advertisement

Platform Rotate: Platform level and completely rotated
one direction. Rotate the opposite direction, Record Time.
Rotate the other direction, Record Time.
Articulating Jib: Platform level and centered with the
boom. Start with the Jib down. Jib Up, Record Time. Jib
Down, Record Time.

Test Notes

1. Stop watch should be started with the function, not
with the controller or switch.
2. All speed tests are run from the platform. These
speeds do not reflect the ground control operation.
3. The platform speed knob control must be at full
speed (turned clockwise completely).
4. Function speeds may vary due to cold, thick hydrau-
lic oil. Test should be run with the oil temperature
above 100° F (38° C).
5. Some flow control functions may not work with the
speed knob clicked into the creep position.

1.5 TORQUE REQUIREMENTS

Table 1-2. Torque Requirements
Description
Torque Value (Dry)
Bearing To Chassis
Bearing To Turntable
Wire Rope
M16 Travel motor
mounting bolts
M20 Final Drive
mounting bolts
M20 Track roller
mounting bolts
M24 Carrier roller
mounting bolts
*Check swing bearing bolts for security after first 50 hours of opera-
tion and every 600 hours thereafter. (See paragraph on Swing Bearing
in Section 2.)
NOTE: When maintenance becomes necessary or a fas-
tener has loosened, refer to the Torque Chart to
determine proper torque value.
3120794
Interval Hours
See Note
50/600*
See Note
50/600*
15 ft.lbs.
150
(20 Nm)
175 ±30 ft.lbs.
As
(240±40 Nm)
required
390 ±50 ft.lbs.
As
(530±70 Nm)
required
340 ±44 ft.lbs.
As
(460±60 Nm)
required
600 ±70 ft.lbs.
As
(800±100 Nm)
required

1.6 LUBRICATION

Deutz F4M1011F Engine

Single Viscosity Oil (CD-SE, CD-SF).
When Outside Temperature is
Consistently
-20°F. to +25°F. (-29°C. to +4°C.)
+5°F. to +50°F. (+15°C. to +10°C.)
+40°F. to +85°F. (+4°C. to +30°C.)
Above 75°F. (24°C.)
Multi Viscosity Oil (CD-SE, CD-SF)
*This viscosity can be used at colder temperatures with
engine oil preheating.
When Outside
Temperature is
Consistently
-40°F. to +75°F. (-40°C. to
+24°C.)
-15°F. to +70°F. (-26°C. to
+21°C.)
-15°F. to +85°F. (-26°C. to
+30°C.)
Above -5°F. (-21°C.)
-5°F. to +75°F. (-21°C. to
+24°C.)
*This viscosity can be used at colder temperatures with
engine oil preheating.
NOTE: Crankcase oil should be MIL-L2104B/MIL-L2104C or
have properties of API classification CC/CD grades.
– JLG Lift –
SECTION 1 - SPECIFICATIONS
Use SAE Viscosity
Number
*10W
20W-20
30
40
Use SAE Viscosity Number
*5W-30 (Synthetic)
10W-30
10W-40
15W-40
15W-30
1-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

600sc660sjc

Table of Contents