Table 6-2. Machine Configuration Programming Information (Software Version P2.10)
Configuration
Number
Label/Digit
TILT:
1
9*
2
3
4
5
6
7
8
9
10
11
12
* Certain market selections will limit tilt options and alter default setting.
* Drive Reversal feature of X DEG + DRV CUT does not apply to crawlers.
Note: Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform alarm when the machine is also above elevation..
JIB:
1
10
2
* Certain model selections will limit visibility.
SOFT TOUCH:
1
11
2
3121671
5 DEGREES: Reduces the maximum speed of all boom functions tocreep when tilted more than 5 degrees and above
elevation; alsoreduces drive speed to creep.
4.5 DEGREES: Reduces the maximum speed of all boom functions to creepwhen tilted more than 4.5 degrees and above
elevation; also reduces drivespeed to creep.
4 DEGREES: Reduces the maximum speed of all boom functions to creepwhen tilted more than 4 degrees and above
elevation; also reduces drivespeed to creep.
3 DEGREES: Reduces the maximum speed of all boom functions to creepwhen tilted more than 3 degrees and above
elevation; also reduces drivespeed to creep.
5 DEG + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 5 degrees and above
elevation; also disallows tower lift up, drive, telescope out and lift up.
4.5 DEG + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 4.5 degrees and
above elevation; also disallows tower lift up, drive, telescope out and lift up.
4 DEG + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 4 degrees and above
elevation; also disallows tower lift up, drive, telescope out and lift up.
3 DEG + CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 3 degrees and above
elevation; also disallows tower lift up, drive, telescope out and lift up.
5 DEG + DRV CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 5
degrees and above elevation; also reduces drive speed to creep when drive reversal is allowed, drive is
disallowed otherwise.
4.5 DEG + DRV CT: Reduces the maximum speed of all boom functions to creep when tilted more than 4.5 degrees and
above elevation; also reduces drive speed to creep when drive reversal is allowed, drive is disallowed otherwise.
4 DEG + DRV CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 4 degrees and
above elevation; also reduces drive speed to creep when drive reversal is allowed, drive is disallowed otherwise.
3 DEG + DRV CUT: Reduces the maximum speed of all boom functions to creep when tilted more than 3 degrees and
above elevation; also reduces drive speed to creep when drive reversal is allowed, drive is disallowed otherwise..
NO: No jib installed.
YES: Jib installed, which has up and down movements only.
NO: No Soft Touch system installed.
YES: Soft Touch system installed.
SECTION 6 - JLG CONTROL SYSTEM
Description
Default
Number
9
2
1
6-21