JLG 400S Service And Maintenance Manual page 244

Table of Contents

Advertisement

SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
523470
2
827
146
523470
7
876
146
523470
11
831
146
523470
11
832
146
523470
12
828
146
523470
12
829
146
523470
14
830
146
3-186
Table 3-16. Deutz Engine Fault Codes
Description
The pressure relief valve (PRV) has been
opened due to excessive pressure.
Rail pressure is out of the expected average
range.
Rail pressure relief valve can not be opened
due to the rail pressure.
Rail pressure is out of the expected average
range.
The PRV can not be opened at this
operating point with a pressure shock.
Rail pressure relief valve: is open. Shutoff
conditions.
Rail pressure relief valve is open. Warning
conditions.
Rail pressure relief valve is open. (PRV)
Possible Cause
Rail pressure has exceeded the trigger
threshold of the pressure limiting valve.
Rail pressure is out of the expected average
range.
PRV can not be opened.
Rail pressure out of tolerance range (PRV can
not be opened by a pressure peak in this
operating point)
Averaged rail pressure is outside the expected
tolerance range.
Shut Off after PRV Open
Warning PRV open
Open PRV
Action
Threshold for error detection is an internal ECU
threshold.
Reset the fault and at reappearance check
injection system.
(A) Check rail pressure relief valve and replace
if necessary.
(B) Check high pressure pumps, pressure relief
valve and metering unit.
(C) Change components if necessary
Threshold for error detection is an internal ECU
threshold.
Check rail pressure, check rail pressure sensor
for plausibility, check FCU.
Threshold for error detection is an internal ECU
threshold.
Check PRV and replace if necessary.
Threshold for error detection is an internal ECU
threshold.
Check PRV opening counter and if necessary
replace PRV,
check rail-pressure sensor for plausibility and
if
necessary replace it,
check FCU and if necessary replace it.
Threshold for error detection is an internal ECU
threshold.
Check PRV opening counter and if necessary
replace PRV,
check rail-pressure sensor for plausibility and
if necessary replace it,
check FCU and if necessary replace it.
Threshold for error detection is an internal ECU
threshold.
Only after ECU reset.
Check PRV opening counter and if necessary
replace it,
check rail-pressure sensor for plausibility and
if necessary replace it,
check FCU and if necessary replace it.
3121671