SECTION 6 - JLG CONTROL SYSTEM
Help Message
DTC
GROUND MODULE FAIL-
9921
URE:HIGH SIDE DRIVER CUTOUT
FAULTY
PLATFORM MODULE FAILURE:
9922
HWFS CODE 1
FUNCTIONS LOCKED OUT -
9924
MACHINE NOT CONFIGURED
GROUND MODULE CONSTANT
9927
DATA UPDATE REQUIRED
CURRENT FEEDBACK GAINS
9944
OUT OF RANGE
CURRENT FEEDBACK CALIBRA-
9945
TION CHECKSUM INCORRECT
6-88
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
The engine is not running
The engine is not cranking
The UGM footswitch input J7-15 is LOW
The machine is in Platform Mode
The Main Dump output J2-13 is detected as HIGH via
the analog feedback 300ms after it is attempted to be
activated during the one time startup test of the UGM
hardware shutoff circuitry
The PM detects that its V(low) FET has failed and
reports this fault to the UGM
The machine is powered up and no model has been
selected yet in the MACHINE SETUP menu
The UGM detects one of the following conditions when
software type is 'P' or 'B':
The Version Verification Word #1 or the Version Verifica-
tion Word #2 values located in the constant data sector
of flash memory (found on constant data spreadsheet
tab pstConstantDataVersion) do not match the values
located in the code area of flash memory
The Version Major value located in the constant data
sector of flash memory (found on constant data
spreadsheet tab pstConstantDataVersion) does not
match the value located in the code area of flash mem-
ory
One or more of the current feedback gains that are cal-
culated and written to flash memory during the PIC
manufacturing test process are detected as being out of
range
The current feedback gains checksum that is calculated
and written to flash memory during the PIC manufac-
turing test process is detected as being incorrect
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
Disable all Drive/Steer
Power Cycled
and Boom functions
except Tower Lift Down
(340AJ, 450AJ), Lift
Down, and Jib Lift Down
(340AJ).
No response required for
Power Cycled
this DTC
Display??? or NO MODEL at
Power Cycled
Analyzer MACHINE SETUP
menu MACHINE SETUP-
>MODEL NUMBER
Do not report any other
faults
Disable all machine and
engine functions (i.e.,
command engine shut-
down and do not permit
start)
Disable all machine and
A different application code or constant
engine functions (i.e.,
data version is programmed so that the val-
command engine shut-
ues match
down and do not permit
Power Cycled
start)
A gain of 1 is used for the
Power Cycled
factory gain(s) that was
out of range; all functions
shall be placed in Creep
mode.
Disable all machine and
Power Cycled
engine functions (i.e.,
command engine shut-
down and do not permit
start).
X
X
X
X
X
X
X
X
X
X
X
X
3121671