SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
677
3
960
512
677
4
957
512
677
4
961
512
677
5
958
512
677
12
959
512
691
8
928
928
729
3
549
263
729
4
551
263
3-168
Table 3-16. Deutz Engine Fault Codes
Description
Start relay (low side power stage): the cur-
rent drain measured by ECU is above the
tar- get range.
Start relay (high side power stage):
the current drain measured by ECU is above
the target range.
Start relay (low side power stage): the cur-
rent drop measured by ECU is above the
tar- get range.
Start relay (low side power stage): the cur-
rent drop measured by ECU is above the
tar- get range
Start relay (low side power stage): the cur-
rent drop measured by ECU is above the
tar- get range.
Supply module heater: PWM time period
out of valid range.
wiring to the intake air heater device is
faulty.
wiring to the air intake heater is faulty
Possible Cause
Shortcut LowSide-Output to battery.
Shortcut HighSide-output to ground.
Shortcut LowSide-Output to ground.
Open circuit/disconnection LowSide-Output.
Temperature over limit.
PWM signal for temperature readout from
sup- ply module to the control unit is out of
range.
Supply modul defect, fault in the wiring.
Intake Air Heater Device: overload, short-
circuit
Relay (for cold start aid) cable break or short to
ground:
Action
Threshold for error detection is an internal ECU
threshold.
Check cabling and start relay and if necessary
replace it,
check connection cable and if necessary repair
or replace it.
Threshold for error detection is an internal ECU
threshold.
Check cabling and start relay and if necessary
replace it,
check connection cable and if necessary repair
or replace it.
Threshold for error detection is an internal ECU
threshold.
Check cabling and start relay and if necessary
replace it,
check connection cable of terminal 50 and if
necessary repair or replace it.
Threshold for error detection is an internal ECU
threshold.
Check cabling and start relay and if necessary
replace it,
check connection cable and if necessary repair
or replace it.
Threshold for error detection is an internal ECU
threshold.
Check cabling and start relay and if necessary
replace it,
check connection cable and if necessary repair
or replace it.
The Time period of the received PWM signal
SCR_tiSMPerPwm is within the specified
range of150ms to 250ms
Supply module check and replace if necessary.
Check the wiring.
Threshold for error detection is an internal ECU
threshold.
Electrical error, Check wiring to the intake air
heater device.
Threshold for error detection is an internal ECU
threshold.
Electrical error, check wiring to the air intake
heater.