JLG 400S Service And Maintenance Manual page 247

Table of Contents

Advertisement

Deutz
Blink
SPN
FMI
Code
Code
523612
12
628
555
523612
12
629
555
523612
12
630
555
523612
12
631
555
523612
12
632
555
523612
12
633
555
523612
12
634
555
523612
12
635
555
523612
12
636
555
523612
12
637
555
523612
12
638
555
3121671
Table 3-16. Deutz Engine Fault Codes
Description
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged
internally; no item will be created in error
memory
The two voltage values (ADC_VAL1,
ADC_VAL2), detected by
the accelerator pedal, are not plausible to
each other.
Impermissible offset between the engine
speed of level 2 and level 1
Diagnostic fault check to report the
plausibility error between level 1
energizing time and level 2 information
Error in the plausibility of the start of
energising angles
Error in the plausibility of the energising
times of the zero fuel quantity calibration
Error in the plausibility of PoI2 efficiency.
Error in the PoI2 shut-off.
Error in the plausibility of PoI3 efficiency.
Engine speed: the engine speed calculated
by ECU is above the target range; the ECU
activates a system reaction
Error in the plausibility of the wave
correction parts
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
Error in the check of the shut-off path test of
the over voltage detection (ECU internal
error). Diagnostic fault check to report the
error
in overvoltage monitoring
Defect pedal or wiring
Calculated engine speed in level 1/2
implausible (-> ECU internal error).
Implausible injection energizing time for
either
PiIx or MI1 or PoIx.
Implausible start of energising of either PiIx or
MI1 or PoIx.
The energising times of the zero fuel quantity
calibration ZFC is out of the target. (->
ECU internal error)
Error in the plausibility of PoI2 efficiency.
Error in the PoI2 shut-off.
Error in the plausibility of PoI3 efficiency.
Error in the plausibility of current energising
time with maximum permitted energising
time. Diagnostic fault check to report the error
due to OverRun
Error in the plausibility of the wave correction
parts
Action
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
Check Pedal, repair or exchange the Pedal.
Check wiring.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
3-189