JLG 400S Service And Maintenance Manual page 529

Table of Contents

Advertisement

Help Message
DTC
MACHINE CONFIGURATION
9949
OUT OF RANGE – CHECK ALL
SETTINGS
LSS CORRUPT EEPROM
9977
FUNCTIONS LOCKED OUT -
9979
GROUND MODULE SOFTWARE
VERSION IMPROPER
GROUND MODULE VLOW FET
9986
FAILURE
LSS INTERNAL ERROR
99171 MACHINE SETUP > LOAD SYSTEM ≠ NO;
LSS - FACTORY CALIBRATION
99285 The load sensor is reporting a factor calibration issue
ERROR
3121671
Table 6-11. Diagnostic Trouble Code Chart
Fault Condition/Trigger
(For configurable items, fault applies only if
configured. All listed conditions to be met
unless stated otherwise)
UGM has detected an anomaly in EEPROM with regard
to the Machine Setup configuration.
MACHINE SETUP > LOAD SYSTEM ≠ NO;
Load System is the 4-Cell LSS;
and one of the following conditions:
UGM determines LSS-stored values for Unloaded
weight in Indirect 0x100≠ 0x108 or
UGM determines LSS-stored values for Accessory
weight in Indirect 0x102≠ 0x10A
UGM determines LSS-stored checksum1 (0x10F) ≠
checksum 2 (0x107)
Ground software has been installed on a UGM with a
ST10F274 processor (Hardware Rev < 6), which does
not have guaranteed flash storage in the sector where
Constant Data is written.
VLow FET determined to be failed because all Digital
Inputs are high; UGM unable to read high-sensing
inputs.
Load System is the 1-Cell LSS;
Strain Gauge 1 or 2 reports Initialization, Defect or Not
Installed error
(internal error)
The machine will assume the platform is overloaded.
This fault, once annunciated is latched within a given
key cycle.
SECTION 6 - JLG CONTROL SYSTEM
Required Control
Conditions Required for Movement
Response or State
and/or to Clear Fault
Assignment
UGM to prompt operator
Power Cycled and EEPROM data in associ-
to correct issue via Ana-
ated area is changed
lyzer and disable all
machine and engine func-
tions (i.e., command
engine shutdown and do
not permit start).until
EEPROM data in corrupted
area is changed.
UGM to set Platform Load
Power Cycled
State = Overloaded
Disable all machine and
Power Cycled
engine functions (i.e.,
command engine shut-
down and do not permit
start)
Disable all machine and
Power Cycled
engine functions (i.e.,
command engine shut-
down and do not permit
start).
UGM to set Platform Load
Power Cycled
State = Overloaded
Possible sensor hardware issue.
X
X
X
X
X
X
X
X
X
X
6-89