VALVE SEALING TEST

1. Clean and dry the combustion chamber area
2. Pour a small amount of clean solvent into intake port
w
and check for leakage around the valves. The
valve seats should hold fluid with no seepage.
3. Repeat for exhaust valve by pouring fluid into exhaust
e
port
.
9929758 R01 - 2019 TAYLOR-DUNN G-100 Service Manual
© Copyright TAYLOR-DUNN
VALVE CLEARANCE CHECK /
ADJUSTMENT
q
.
Always inspect valve clearance prior to camshaft
installation or final engine assembly.
Valve clearance should only be checked on a cold
1. Install the cam chain guides and cam chain before
camshaft installation (if removed) as outlined in this
chapter.
2. Lubricate the camshaft bearing journal surfaces with
5W-50 full synthetic engine oil prior to installation.
3. Carefully install the camshafts into the cylinder head.
The camshaft lobes should face out.
4. Carefully install the camshaft carrier onto the
camshafts.
5. Install the four bolts that retain the camshaft carrier.
ENGINE / COOLING SYSTEM
NOTE
NOTE
engine.
3