Taylor-Dunn G0-010-00 Service And Replacement Parts Manual page 146

Table of Contents

Advertisement

ENGINE / COOLING SYSTEM
BALANCE SHAFT INSTALLATION / TIMING
1. Position balance shaft in the crankcase.
2. Rotate crankshaft to align the timing marks
shown below.
3. Fully seat the balance shaft into the crankcase and
verify timing marks are correct.
3.86
FINAL CRANKCASE ASSEMBLY
1. Prepare MAG side crankcase by cleaning sealing
surface. Be sure the oil pickup and oil pressure valve
q
as
are fully installed.
2. Apply a thin film of Crankcase Sealant (PN 2871557)
evenly to a clean and oil-free MAG crankcase mating
surface as indicated below
w
are in place.
Crankcase Sealant: 2871557
3. Assemble MAG crankcase to PTO crankcase
immediately. Do not allow sealant to dry.
4. Tap crankcase evenly until fully seated with a soft
sided hammer.
5. Install the new crankcase bolts finger tight in MAG
side crankcase.
6. Tighten all bolts evenly until snug.
9929758 R01 - 2019 TAYLOR-DUNN G-100 Service Manual
q
. Be sure alignment pins
© Copyright TAYLOR-DUNN