7
MES INTERFACE FUNCTION CONFIGURATION TOOL
7.6.1 Setting items in Network setting
Configure the settings necessary for connecting the MES interface module to the network.
Table 7.22 Setting items in [Network settings]
Item
Set the IP address of the MES interface module in decimal notation.
IP address (required)
(Default: 192.168.3.3)
Set the subnet mask in decimal notation.
Subnet mask (required)
All devices on the same network must use the same subnet mask.
(Default: 255.255.255.0)
Set the default gateway in decimal notation.
Default gateway
One default gateway can be registered for the MES interface module.
(Default: No setting)
Before entering values in [Network settings], consult your network administrator
(the person who plans networking and manages IP addresses).
Figure 7.20 [Network settings]
Description
7.6 System Setting
7.6.1 Setting items in Network setting
1
2
3
4
5
6
7
8
7
- 19