7
MES INTERFACE FUNCTION CONFIGURATION TOOL
7
- 106
7.11 Job Setting - Actions
7.11.2 Setting items in Communication action (Select/Update/Insert/MultiSelect/Delete)
Data base (before sorting)
ORDER_NO
PRODUCT_CODE
200
201
202
203
204
205
206
207
208
Sorting conditions in [Select sort settings]
1)
2)
Selected records [sorting results]
ORDER_NO
PRODUCT_CODE
206
204
2)
201
207
205
2)
202
208
203
2)
200
1) First, selected records are sorted in ascending order of DELIVERY_DATE.
2) Then, records of the same DELIVERY_DATE are sorted in descending order of ORDER_NO.
Figure 7.83 Operation example of [Select sort settings
DELIVERY_DATE
707
2007-01-31
662
2007-01-10
666
2007-01-29
662
2007-01-31
707
2007-01-10
666
2007-01-29
707
2007-01-10
662
2007-01-29
662
2007-01-31
DELIVERY_DATE
707
2007-01-10
707
2007-01-10
662
2007-01-10
662
2007-01-29
666
2007-01-29
666
2007-01-29
1)
662
2007-01-31
662
2007-01-31
707
2007-01-31