7
MES INTERFACE FUNCTION CONFIGURATION TOOL
Remark
7
- 104
7.11 Job Setting - Actions
7.11.2 Setting items in Communication action (Select/Update/Insert/MultiSelect/Delete)
(a) Combine
Select a method by which conditions set in respective lines are combined.
Select "AND" or "OR".
If "AND" and "OR" are combined, the database will process "AND" first and then
"OR".
(b) Field name (Up to 32 characters)
Set a field name that is used for comparison.
For characters that can be used for field and table names, refer to the following:
Appendix 2.4 Characters available for field names, table names, stored
procedure names,etc.
For browsing the field names in the database, refer to the following:
(8) Browse field name in this section
(c) Condition
Select a condition for comparison.
Item
=
>
<
(d) Tag
Select a tag or constant that is used as a condition for comparison.
Note that tags with [Array setting] are not selectable.
(e) Component
Select or directly enter a component/constant value that is used as a condition for
comparison.
If [Variable] is selected for [Tag], select or directly enter a variable.
For tag components, constants or variables, refer to the following:
• Section 7.11.1 (1) About tag components
• Section 7.11.1 (2) About constants
• Section 7.11.1 (3) About variables
Table 7.74 Selection items for [Condition]
The field value is equal to the condition value.
The field value is not equal to the condition value.
The field value is equal to or greater than the condition value.
The field value is greater than the condition value.
The field value is smaller than the condition value.
The field value is equal to or smaller than the condition value.
Description