(2) Trigger monitoring function
The operation conditions for starting a job are as described below.
(a) For an MES interface module whose first five digits of serial No. is "11011" or
earlier
The job can be started only when the device tags used for trigger conditions of all
jobs have been sampled normally.
(b) For an MES interface module whose first five digits of serial No. is "11012" or later
The job can be started when the device tags used for trigger conditions of the job
have been sampled normally.
The job can be started even if device tags used for another job's trigger conditions
have not been sampled normally.
Appendix 1 Functions Added in MES Interface Module and MX MESInterface
Appendix 1.3 Operations of former versions