10
TROUBLESHOOTING
Error code
C000h
to
CFFFh
D000h
to
DFFFh
E000h
to
EFFFh
F000h
to
FEFFh
FFD0h
FFD1h
FFD2h
to
FFD4h
FFD5h
FFD6h
FFD7h
FFD9h
to
FFDEh
FFDFh
FFE0h
FFE1h
FFEDh
to
FFEFh
FFF0h
FFF1h
FFF2h
FFF3h
FFF4h
Table 10.3 Error codes for the MES interface module
Error name
Errors detected in the Ethernet interface module
User's manual of Ethernet interface module
Errors detected in CC-Link IE Field Network
CC-Link IE Field Network Master/Local Module User's Manual
Errors detected in CC-Link IE Controller Network
CC-Link IE Controller Network Reference Manual
Errors detected in the MELSECNET/H (10) network system
Q Corresponding MELSECNET/H (10) Network System Reference Manual
System error
Monitor condition
Reading is not possible because the
dissatisfied error
monitor condition is not met.
System error
Writing a TC setting value was
attempted to the programmable
ROM operation error
controller CPU that was running the
ROM.
System error
Incorrect access target
The setting of the access target CPU
error
is incorrect.
System error
Station or Network No.
The station No. or network No. is out
error
of range, or the setting is incorrect.
System error
No memory cassette or inappropriate
Memory cassette error
one is attached to the accessed
programmable controller CPU.
The block No. of the specified
extension file register has been
Write protect error
allocated to the write-protect area of
the memory cassette.
The block No. of the specified
Block error
extension file register is invalid.
Description
10.2 Error Code List
10.2.1 Error codes for the MES interface module
(From the previous page)
Action
• Please consult your local Mitsubishi
representative.
• Delete the monitor condition by GX
Developer.
• Please consult your local Mitsubishi
representative.
• Change the TC setting value during
ROM operation.
• Please consult your local Mitsubishi
representative.
• Correct [Access target CPU
settings].
• Please consult your local Mitsubishi
representative.
• Check the station No. and network
No. in [Access target CPU settings].
• Please consult your local Mitsubishi
representative.
• Check the memory cassette of the
access target CPU.
• Check the block No. of the
extension file register (device type).
• Check the write-protect DIP switch
on the memory cassette of the
access target CPU.
• Check the block No. of the
extension file register (device type).
(To the next page)
10
9
10
- 22