Mitsubishi Electric Melsec Q Series User Manual page 108

Programmable contoller mes interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

4
SETTINGS AND PROCEDURE TO OPERATION
(3) Response monitoring time setting (Switch 3 (Lower byte))
b15
*The upper byte data is ignored. However, when other than 0 is specified
in this area, "Switch setting error" (0180h) occurs at hardware test.
Remark
4
- 11
4.5 Intelligent Function Module Switch Settings
Use the default operation setting when changing the settings of the MES interface
module connected to the configuration computer on a 1:1 basis.
(b) Battery error detection setting (bit 2)
Set whether to detect battery errors while the QJ71MES96 MES interface module
is operating without battery. (
0: Detects battery errors.
1: Does not detect battery errors.
Set the timeout time (Second) from when the MES interface module sends a request
to the access target CPU until receiving the reply.
A response time-out error (0002h) occurs if the access target CPU does not respond
within the set time.
Setting range: 15 to 255 (Second) (Default value: 15 seconds)
When setting the time between 0 and 14 or making no settings, response monitoring
time operates with 15 seconds.
to
b8 b7
(Upper byte)*
Specify "0".
Figure 4.10 Response monitoring time setting (Switch 3 (Lower byte))
After Write to PLC is executed, the intelligent function module switch settings are
enabled when turning the power ON from OFF, or resetting the programmable
controller CPU.
For GX Developer operation method, refer to the following manual.
GX Developer Operating Manual
Section 4.9 Operation without Mounting Battery)
to
b0
(Lower byte)
Switch 3
Response monitoring time setting
15 to 255 (Second)
When setting the time between 0
and 14 or making no settings,
response monitoring time operates
with 15 seconds.