7.10.1 Setting items in Job setting

Up to 64 items can be set in [Job settings] within one project.
For job operations, refer to the following:
Section 6.1.11 (1) Operation behavior of jobs
Job name
Enable at module startup
Trigger buffering
Startup logging
Test mode
Trigger conditions
Actions
Program execution
DB Buffering
Notify errors (job
cancellation) that occur
during job execution
No. of fields in project
No. of fields in job
Tag component data length
in job
Figure 7.43 [Job settings]
Table 7.46 Setting items in [Job settings]
Item
Enter a job name. (Up to 16 characters)
Set whether to enable the job at startup of the MES interface module or not.
Set whether to enable the trigger buffering or not.
Set whether to output the startup history of the job to the log or not.
Set whether to operate the job in test mode or not.
Configure the settings for startup conditions of the job.
Section 7.10.2 Setting items in Trigger conditions
Configure the action settings.
Section 7.11 Job Setting - Actions
Configure the settings for the program execution function.
Section 7.10.3 Setting items in Program execution
Set whether to utilize the DB buffering function or not.
Section 7.10.4 Setting items in DB Buffering
Set whether to enable or disable notification of errors (job cancellation) that
occur during job execution.
Section 7.10.5 Setting items for job cancellation
Displays the total number of fields in the project.
Displays the total number of fields used in [Job settings].
Displays the total data length of the tag components in the job.
Description
7.10 Job Setting
7.10.1 Setting items in Job setting
1
2
3
4
5
6
7
8
7
- 59