MES INTERFACE FUNCTION CONFIGURATION TOOL
(1) Job name (Up to 16 characters)
(2) Enable at module startup
(3) Trigger buffering
7
- 60
7.10 Job Setting
7.10.1 Setting items in Job setting
Enter a job name.
For characters that can be used for job names, refer to the following:
Appendix 2.2 Characters that can be used for item names, component names,
variable names, etc. in the product
(a) Set whether to enable the job at startup of the MES interface module or not.
If the [Enable at module startup] box is not checked, the job is disabled at startup
of the module. (Even if trigger conditions are met, the job is not executed.)
(b) While the MES interface module is operating, this setting can be changed by the
following:
• "Instruction of job execution" in the XML processing function
Section 6.2 XML Processing Function
• [Online] - [Remote operation] - [Change job status]
Section 7.13.4 Changing the job status
(a) Set whether to enable the trigger buffering function or not.
For the trigger buffering function, refer to the following:
Section 6.1.5 Trigger buffering function
(b) Precautions when selecting [Trigger buffering]
1) [Handshake operation] is not selectable for trigger conditions.
2) No tag component can be selected for the following items:
• Substitution tag of [Select] in [Communication action]
• Substitution tag of [Operation action]
• Output arguments , input/output arguments, and returned values of stored
procedures
3) [Communication action] - [MultiSelect] cannot be selected.
4) Up to 4096 words
in one job. (The setting can be checked on the status bar of [Job settings] or in
each action dialog box.)
*1
The total data length of the tag components that are set in [DB-tag link settings] or [Select/Update/
Delete conditions] of [Communication action], or in [Operation action].
If two or more identical tag components are set in the same job, respective data lengths are
counted.
5) When Delete is used for Communication action and if it is executed, the
deleted record cannot be restored.
6) When multiple jobs for which [Trigger buffering] is enabled are set, the next job
is not performed until the execution of other jobs are complete.
*1
can be set as the total tag component data length usable