Precautions - Mitsubishi Electric Melsec Q Series User Manual

Programmable contoller mes interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

7
MES INTERFACE FUNCTION CONFIGURATION TOOL

7.15 Precautions

This section provides precautions for using MES Interface Function Configuration Tool.
(1) When deleting an item
(2) Changing [PLC series] in [Access target CPU settings]
(3) Changing the [Prohibit data writing] setting in [Device tag settings]
(4) One-shot execution
7
- 146
7.15 Precautions
Deleting an item such as [Access target CPU settings] or [Device tag settings] is not
allowed when the selected item is used for another item such as [Job settings].
As the error dialog box appears, identify the location, stop using it for another item,
and then delete the item.
The CPU type set for [PLC series] of [Access target CPU settings] cannot be changed
if the change may generate illegal character strings of the devices for the tag
components for which [Access target CPU settings] is selected.
The enabled data write setting cannot be changed to "Prohibit" if the tag is used for
the setting items provided for tag writing.
• [Completion notification] of [Handshake operation], substitution tags of [Select] in
[Communication action], etc.
When performing the one-shot execution, set the same settings for the system
settings being used on the MES interface module and the system settings of the
project currently opened with the MES Interface Function Configuration Tool.
During one-shot execution, do not turn the power of programmable controller OFF
and then ON, nor reset the programmable controller CPU.
When the one-shot execution is not completed normally by performing the above
operations or due to a communication error, write a project again and perform [Update
settings].
For [Update settings], refer to the following:
Section 7.13.2 (3)
Figure 7.115 Error dialog box

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71mes96Qj71mes96nSw1dnc-mesif-e

Table of Contents