SETTINGS AND PROCEDURE TO OPERATION
(2) Starting the MES interface module
Mount a battery to the QJ71MES96 MES interface module.
Mount the MES interface module to a base unit.
Connect the MES interface module to the configuration computer on a 1:1 basis.
Section 2.1.3 System configuration for initial setup
Power ON the programmable controller.
RUN LED is turned ON and ERR. LED flashes on the
MES interface module.
Install a CompactFlash card to the MES interface
module.
*4
4
- 3
4.2 Settings and Procedure to Operation
Start the server computer, and then the MES interface module.
(1) Starting the server computer in this section
Procedure to operation
MES interface module
(To the next page)
Figure 4.2 MES interface module start-up procedure
*1
Install MES Interface Function Configuration Tool.
Section 5.1 Installation
*2
Start MES Interface Function Configuration Tool.
Confirm the outline of MES Interface Function
Configuration Tool.
• Section 7.2 Starting the MES Interface Function
Configuration Tool
• Section 7.3 Screen Structure
• Section 7.4 Project File Handling
• Section 7.5 Project Setting
Format the CompactFlash card.
Section 7.13.8 Formatting the CompactFlash card
Select [System setting] and make [Network settings].
Section 7.6.1 Setting items in Network setting
Configuration computer
*3
(To the next page)