TROUBLESHOOTING
Table 10.5 Event log output error list of DB Connection Service (source name: DBConnector)
Error code
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
10
- 25
10.2 Error Code List
10.2.2 Error codes of DB Connection Service
Error description and cause
The setting file path is too long.
The setting file name indicates the directory.
The setting file could not be opened.
Description of the setting file is not correct.
Parameter specification of the setting file is not
correct.
The version of the setting file is not correct.
The server port No. setting is not correct.
The server port No. setting is out of range.
The DB access timeout time setting is not correct.
The DB access timeout time setting is out of range.
There are too many connection-permitted IP
address settings.
Description of the connection-permitted IP address
setting is not correct.
The mask bit length setting of the connection-
permitted IP address is not correct.
The mask bit length setting of the connection-
permitted IP address is out of range.
The access log setting is not correct.
The setting of the access log file name is not
correct.
The access log file name is too long.
The maximum file size setting for the access log is
not correct.
The maximum file size setting for the access log is
out of range.
The maximum number of access log files is not set
correctly.
The maximum number of access log files is out of
range.
The SQL failure log setting is not correct.
The setting of the SQL failure log file name is not
correct.
The SQL failure log file name is too long.
The maximum file size setting for the SQL failure
log is not correct.
The maximum file size setting for the SQL failure
log is out of range.
The maximum number of SQL failure log files is not
set correctly.
The maximum number of SQL failure log files is out
of range.
(From the previous page)
Corrective action
• Reinstall the DB Connection Service to the
directory whose path name is shorter.
• Reinstall the DB Connection Service.
• Terminate other applications, and make the
setting again with DB Connection Service Setting
Tool.
• Configure the settings again with DB Connection
Service Setting Tool.
(To the next page)