TROUBLESHOOTING
Error code
062Eh
062Fh
0630h
0631h
0649h
064Bh
064Ch
0650h
0659h
06A0h
06AAh
06ABh
06ADh
0830h
0831h
0832h
08A1h
08A2h
08B0h
08B1h
10
- 11
10.2 Error Code List
10.2.1 Error codes for the MES interface module
Table 10.3 Error codes for the MES interface module
Error name
There is an inconsistency between the
device and data type that were
specified in the "component setting".
Data type incorrect error
(Any other than Bit was specified for a
bit device, or Bit was specified for any
other than bit device.)
The number of characters specified in
Excessive number of
the "component setting" is out of
characters error
range.
The decimal or exponential type
Decimal/Exponential form
specification in the "component
setting error
setting" is invalid.
Failed to read out the setting file. (The
Setting file error
setting file is corrupted.)
Excessive number of
The total of device points for the high-
device points for high
speed sampling tag exceeded 96.
speed sampling tag
High speed sampling tag
Failed to register a component device
component registration
of the high-speed tag to the CPU.
error
Failed to read out the setting file. (The
Setting file error
setting file is corrupted.)
A nonexistent module was specified
Network communication
for [Head I/O] in [Network
route error
communication route] of [Access
target CPU settings].
System error
Failed to read out the setting file. (The
setting file is corrupted.)
No CompactFlash card has been
installed.
Setting file error
Failed to read out the setting file. (The
setting file is corrupted.)
Failed to read out the setting file. (The
setting file is corrupted.)
System error
Description
• Correct the "component setting".
• Correct the "component setting".
• Retry writing the setting with MES
• Change the setting so that the total
• Ensure a system area in the
• For the Redundant CPU, check the
• Retry writing the setting with MES
• Correct the Head I/O address in
• Please consult your local Mitsubishi
• Retry writing the setting with MES
• Install a CompactFlash card.
• Retry writing the setting with MES
• Retry writing the setting with MES
• Please consult your local Mitsubishi
(From the previous page)
Action
Interface Function Configuration
Tool.
device points will not exceed 96.
program memory of the
programmable controller CPU.
(Format the PLC memory.)
system area for the Redundant CPU
of both systems.
Interface Function Configuration
Tool.
[Access target CPU settings].
representative.
Interface Function Configuration
Tool.
Interface Function Configuration
Tool.
Interface Function Configuration
Tool.
representative.
(To the next page)