7.7 Access Target CPU Setting
7.7.1 Setting items in Access target CPU setting
(c) Other station (Different network)
To access a CPU module on another station over two types of networks 1) and 2)
listed in Table 7.34, specify a different network.
No.
1)
2)
• Access from a MELSECNET/H network to a CPU module on another
Ex.
station over CC-Link (2) → 1))
• Access from a C24 network to a CPU module on another station over CC-
Link IE Controller Network (1) → 2))
Set the network type, network No, head I/O address, and station No. used for access.
The setting items vary depending on the specified network type.
Specify "Ethernet" when accessing the built-in Ethernet port of QCPU (Q mode) which
is set the MELSOFT connection extended setting.
To access a CPU on another station, routing parameters must be set in addition to
this setting.
For the routing parameters, refer to the following:
Manual for the network module used
Table 7.36 Network types
Network name
C24
CC-Link
CC-Link IE Controller Network
MELSECNET/10
MELSECNET/H
Ethernet
CC-Link IE Field Network