Access
Import
Import data step-by-
step
Data Management
1.
Select the Manage page in the Main Menu.
2.
Select Data Transfer.
3.
Select Import.
Description of fields
Field
Option
From
Selectable list
To
Instrument
File
Selectable list
Importing a backup folder will overwrite the existing configuration file and
code lists on the instrument, and all existing formats and jobs will be
deleted.
A backup can only be imported if the instrument database structure was
not changed by a firmware update. If the instrument firmware was upda-
ted, it can happen that a backup created before the update cannot be
imported. In this case, downgrade the firmware to the previous used ver-
sion, save the data in the way required and then reload the new firmware.
1.
Press Cont in the Import screen to proceed to the file directory of
the memory device.
2.
Select the file or backup folder to be imported and press Cont.
3.
For a file: Define the Job name for the imported file, and, if reques-
ted, the file definition and layers, and press Cont to import. If a Job
with the same name already exists in the internal memory, a mes-
sage will appear with the options to overwrite the existing job,
attach the new points to the current job, or rename the job for the
file being imported.
If new points are attached to the current job, and the same point ID
already exists, the existing point ID will be renamed with a numerical
suffix. For example, PointID23 will be renamed to PointID23_1. The
maximum renamed suffix is 10, e.g. PointID23_10.
For a backup folder: Take note of the warning message displayed and
press Cont to proceed and import the folder.
Description
Select the memory device.
Only option
Import a single file or a backup folder.