Leica TS03 User Manual page 74

Table of Contents

Advertisement

Access
Enter Station Data
74
1.
Select Apps from the Main Menu.
2.
Select Setup from the Programs Menu.
3.
Select a job. Refer to "6 Apps - Getting Started".
4.
Select F2 Settings:
Set the standard deviation limits for the position, height, Hz ori-
entation, and the Face I-II difference. For Local Resection, define
the positive North or positive East axis. For Resection Helmert,
set the distance weighting that is used in the calculation of the
station height in the Resection. The height weighting can be
configured.
Set Calc.new Scale: Yes to calculate the scale for the setup
methods Resection and Resection Helmert. The scale can then
be set at the end of the Resection calculation. Measured distan-
ces are always reduced with the scale set on the instrument.
The computed scale is applied on the coordinates.
Press Cont to save the limits and return to the Station Setup
screen.
5.
Select F4 Start to begin the app.
Key
Description
Optional for TS07.
Meas H
To measure the instrument height using the integrated
AutoHeight laser plummet. Refer to "Measure Station Height".
1.
Select the desired setup method.
2.
Enter the station number or press Find or List to select an existing
point. If the entered station number can not be found in the current
job, then the Point Search screen appears. Select a different job to
search or press New to enter the coordinates manually. New is only
available for the methods Ori. with Angle, Ori. with Coord. and H-
Trans.
3.
For all methods except Ori. with Angle and Local Resection, press
Cont to continue to the Enter Target Point screen.
For the Ori. with Angle method, Cont continues to the Manual
Angle Setting screen. Refer to "7.2.2 Measuring the Target Points",
"Manual Angle Setting".