Environmental
specifications
Arctic model
Electronic Guide Light
EGL
Automatic corrections
16.7
Use of scale correc-
tion
Atmospheric correc-
tion
Technical Data
Temperature
Type
Operating temperature
[°C]
All
-20 to +50
instruments
Battery
-20 to +50
USB memory
-40 to +85
stick
Protection against water, dust and sand
Type
Protection
All
IP66 (IEC 60529)
instruments
Humidity
Type
Protection
All
Max 95% non condensing.
instruments
The effects of condensation are to be effectively counterac-
ted by periodically drying out the instrument.
Operating temperature [°C]
-35 to +50
Type
Working range
Position accuracy
The following automatic corrections are made:
Line of sight error
Tilting axis error
Earth curvature
Standing axis tilt
Vertical index error
Refraction
Compensator index error
Circle eccentricity

Scale Correction

By entering a scale correction, reductions proportional to distance can be taken
into account.
Atmospheric correction.
Reduction to mean sea level.
Projection distortion.
The slope distance displayed is correct if the scale correction in ppm, mm/km,
which has been entered corresponds to the atmospheric conditions prevailing
at the time of the measurement.
Storage temperature
[°C]
-40 to +70
-40 to +70
-50 to +95
Storage temperature [°C]
-40 to +70
Description
5 m to 150 m (15 ft to 500 ft)
5 cm at 100 m (1.97" at 330 ft)