  • Page 1 Leica MS50/TS50/TM50 User Manual Version 3.0 English...
  • Page 2 Product The type and serial number of your product are indicated on the type plate. Identification Always refer to this information when you need to contact your agency or Leica Geosystems authorised service workshop. Trademarks • Windows is a registered trademark of Microsoft Corporation in the United States and other countries ®...
  • Page 3 Service Description myProducts Add all Leica Geosystems products that you and your company own. View detailed information on your products, buy additional options or Customer Care Packages (CCPs), update your products with the latest software and keep up-to-date with the latest documentation.
  • Page 4: Table Of Contents

    Fixing the Field Controller to a Holder and Pole Connecting to a Personal Computer Power Functions Batteries 4.9.1 Operating Principles 4.9.2 Battery for the TS Instrument 4.9.3 Battery for SmartAntenna 4.10 Working with the Memory Device 4.11 LED Indicators 4.12 Guidelines for Correct Results MS50/TS50/TM50, Table of Contents...
  • Page 5 Conformity to National Regulations 7.11.1 MS50/TS50/TM50 7.11.2 RadioHandle 7.11.3 GS08plus 7.11.4 GS12 7.11.5 GS14 7.11.6 GS15 7.11.7 Dangerous Goods Regulations 7.12 General Technical Data of the Instrument 7.13 Scale Correction 7.14 Reduction Formulas Software Licence Agreement MS50/TS50/TM50, Table of Contents...
  • Page 6: Safety Directions

     Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner. MS50/TS50/TM50, Safety Directions...
  • Page 7: Definition Of Use

    • To ensure that it is used in accordance with the instructions. • To be familiar with local regulations relating to safety and accident prevention. • To inform Leica Geosystems immediately if the product and the application becomes unsafe. • To ensure that the national laws, regulations and conditions for the operation of e.g.
  • Page 8: Hazards Of Use

    Precautions: When setting-up the product, make sure that the accessories are correctly adapted, fitted, secured, and locked in position. Avoid subjecting the product to mechanical stress. MS50/TS50/TM50, Safety Directions...
  • Page 9 Product-specific treatment and waste management information can be downloaded from the Leica Geosystems home page at http://www.leica- geosystems.com/treatment or received from your Leica Geosystems dealer. Only Leica Geosystems authorised service workshops are entitled to repair these prod- WARNING ucts. MS50/TS50/TM50, Safety Directions...
  • Page 10: Laser Classification

    Wavelength 658 nm Maximum average radiant power 0.34 mW 0.33 mW Pulse duration 800 ps 700 ps Pulse repetition frequency (PRF) 100 MHz 1.1 MHz Beam divergance 1.5 mrad x 3 mrad Labelling a) Laser beam 005030_002 MS50/TS50/TM50, Safety Directions...
  • Page 11: Distancer, Measurements Without Reflectors

    2) Do not look through or beside the optical sight at prisms or reflecting objects when the laser is switched on, in laser pointer or distance measurement mode. Aiming at prisms is only permitted when looking through the telescope. MS50/TS50/TM50, Safety Directions...
  • Page 12 Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. λ = 658nm Pav = 1.8mW tp = 1500ps IEC 60825-1:2014 005032_002 MS50/TS50/TM50, Safety Directions...
  • Page 13: Red Laser Pointer

    2) Do not look through or beside the optical sight at prisms or reflecting objects when the laser is switched on, in laser pointer or distance measurement mode. Aiming at prisms is only permitted when looking through the telescope. MS50/TS50/TM50, Safety Directions...
  • Page 14 Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. λ = 658nm Pav = 1.8mW tp = 1500ps IEC 60825-1:2014 005032_002 MS50/TS50/TM50, Safety Directions...
  • Page 15: Autofocus Capability Of Telescope Camera

    Autofocus Capability of Telescope Camera General The models TS50, TM50 I and MS50 of Leica Nova series contain a coaxial telescope camera with autofocus capability. When using the auto focus functions a visible laser beam may emerge from the tele- scope (depending on the focussing mode).
  • Page 16: Automatic Target Aiming Atr

    TM50 TS50 MS50 Wavelength 785 nm Maximum average radiant power 3 mW 4.4 mW 17 ms Pulse duration 29 Hz 180 Hz Pulse repetition frequency (PRF) Beam divergance 11 mrad 25 mrad Labelling a) Laser beam 005030_002 MS50/TS50/TM50, Safety Directions...
  • Page 17: Powersearch Ps

    1.6.7 PowerSearch PS  This is only applicable for MS50 and TS50 I. General The PowerSearch built into the product produces an invisible laser beam which emerges from the front side of the telescope. The laser product described in this section is classified as laser class 1 in accordance with: •...
  • Page 18: Electronic Guide Light Egl

    1.6.8 Electronic Guide Light EGL  This is only applicable for MS50 and TS50 I. General The Electronic Guide Light built into the product produces a visible LED beam which emerges from the front side of the telescope.  The product described in this section, is excluded from the scope of IEC 60825- 1 (2014-05): “Safety of laser products”.
  • Page 19: Laser Plummet

    2) Avoid pointing the beam at other people or at animals. Labelling Laser Radiation Do not stare into the beam Class 2 Laser Product according to IEC 60825-1 (2014 - 05) = 0.95 mW  = 640 nm 005036_001 a) Laser beam b) Exit for laser beam MS50/TS50/TM50, Safety Directions...
  • Page 20: Electromagnetic Compatibility Emc

    WARNING Although the product meets the strict regulations and standards which are in force in this respect, Leica Geosystems cannot completely exclude the possibility that other equipment may be disturbed. There is a risk that disturbances may be caused in other equipment if the product is...
  • Page 21: Fcc Statement, Applicable In U

    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by Leica Geosystems for compliance WARNING could void the user's authority to operate the equipment.
  • Page 22 Labelling GS14 008606_001 Labelling GS15 008607_001 FCC Labelling GEB242 008682_001 MS50/TS50/TM50, Safety Directions...
  • Page 23 Labelling Internal Battery GEB212, GEB222 008611_001 008610_001 MS50/TS50/TM50, Safety Directions...
  • Page 24 Labelling RH16 RadioHandle 008612_001 RH17 008613_001 MS50/TS50/TM50, Safety Directions...
  • Page 25: Description Of The System

    On the TS50/TM50, it incorporates the LO mode to measure extended distances to prisms. On the MS50, the STD mode is used for the whole distance range including extended distance prisms. • Any surface mode. This mode refers to the ability to measure distances without prisms.
  • Page 26 PowerSearch refers to the instrument sensor which enables the automatic rapid finding of a prism. SmartStation A Leica Nova TPS instrument integrated with an add-on GNSS system, comprising hardware and software components, forms a SmartStation. Components of a SmartStation include a SmartAntenna and a SmartAntenna Adapter.
  • Page 27 Internal Flash Memory (1 GB)     Hotshoe interface for RadioHandle   Guide Light (EGL)    Autofocus     Uninterruptible electronic power supply due to internal charging functionality MS50/TS50/TM50, Description of the System...
  • Page 28: System Concept

    GeoC++ development kit in addition to run Windows CE-based applications if GeoCOM robotics (xx.axx) licence is available. Information on the GeoC++ development environment is available on request from a Leica Geosystems representative.  Software upload Uploading software can take some time. Ensure that the battery is at least 75% full before beginning the upload, and do not remove the battery during the upload process.
  • Page 29: Power Concept

    Available capacity: 1 GB.  While other SD cards can be used, Leica Geosystems recommends to only use Leica SD cards and is not responsible for data loss or any other error that can occur while using a non-Leica card. ...
  • Page 30: Container Contents

    GFZ3 or GOK6 diagonal eyepiece i) Manuals and USB documentation card j) Protective cover for instrument, sunshade for objective lens and cleaning cloth k) Container straps l) Room for standard handle m) GEV234 Data transfer cable n) GEB242 battery MS50/TS50/TM50, Description of the System...
  • Page 31 GPR121 circular prism PRO or GZT4 target plate for GPH1 and GPH1 prism holder with GPR1 circular prism h) GAD109 QN-TNC Adapter i) GAT25 radio antenna j) Stylus k) GEB212 or GEB331 batteries l) SLXX RTK modem m) GS14/GS15/GS08plus antenna n) SD card and cover MS50/TS50/TM50, Description of the System...
  • Page 32 GAT1 or GAT2 radio antennas d) GKL311 charger e) GRZ4 or GRZ122 prism f) Standard handle or RadioHandle g) GAD110 adapter for GS14/GS15/GS08plus antenna h) GAD31 screw to stub adapter i) Mini prism spike j) GMP101 mini prism MS50/TS50/TM50, Description of the System...
  • Page 33 GRZ101 mini prism and GAD103 adapter h) GEB331 battery i) GHT63 pole holder clamp j) Tip for mini pole k) GLI115 clip-on bubble for GLS115 mini prism pole l) Field controller and GHT66 holder m) Stylus MS50/TS50/TM50, Description of the System...
  • Page 34: Instrument Components

    Servofocus drive c) Carry handle d) Optical sight e) Telescope with EDM, ATR and, if available, camera sensors. For MS50/TS50 also EGL and f) EGL, for MS50/TS50 g) Overview camera, for MS50/TS50/TM50 I h) PowerSearch, transmitter, for MS50/TS50 i) PowerSearch, receiver, for MS50/TS50...
  • Page 35 GS14 SmartAntenna c) GS08plus SmartAntenna d) GS12 SmartAntenna e) RTK slot-in device f) GAD110 SmartAntenna Adapter g) Communication side cover h) GAD104 SmartAntenna Adapter Instrument components for a) RadioHandle b) Communication side cover 004455_001 MS50/TS50/TM50, Description of the System...
  • Page 36: User Interface

    Function keys F1 - F6 h) ENTER b) Function keys F7 - F12 i) Arrow keys c) ± key j) OK d) Alphanumeric keys k) Fn e) Backspace l) ON/OFF f) Favourites m) Home g) ESC MS50/TS50/TM50, User Interface...
  • Page 37: Operating Principles

    To accept data entered into an editable Tap on the screen outside of the editable field and exit the edit mode field. To open a context-sensitive menu Tap on the item and hold for 2 s. MS50/TS50/TM50, User Interface...
  • Page 38: Autofocus Capability Of Telescope Camera

    A refocus does a small movement of the focussing lense to find the best focus position. Holding for 2 sec The continuous autofocus is started. By pressing the button again or by turing the servofocus wheel, the continuous autofocus is stopped. MS50/TS50/TM50, User Interface...
  • Page 39: Operation

    By using the electronic level, turn the tribrach footscrews (6) to level the instrument precisely. Centre the instrument precisely over the ground point (4) by shifting the tribrach on the tripod plate (2). Repeat steps 6. and 7. until the required accuracy is achieved. MS50/TS50/TM50, Operation...
  • Page 40: Setting Up Smartstation

    Ensure that the interface connection on the underside of the adapter is on the same side as the Communication side cover. 000606_003 Step Description Place the GS15/GS14/GS12/GS08plus antenna onto the adapter by simulta- neously pressing and holding-in the two press clips. MS50/TS50/TM50, Operation...
  • Page 41: Setting Up Smartpole

    GS12 instrument b) GRZ122 360° prism c) CTR radio cap d) GLS12 cm/GLS12F ft pole with snap-lock positions e) Field controller f) GHT62 holder and GHT63 clamp g) RadioHandle h) Communication side cover, integrated i) Instrument j) Tripod TS_147 MS50/TS50/TM50, Operation...
  • Page 42: Setting Up For Remote Control (With The Radiohandle)

    Setting up for Remote Control (with the RadioHandle) Setup for remote control with RadioHandle a) 360° prism b) Prism pole c) CTR radio cap d) Field controller e) GHT62 holder and GHT63 clamp f) RadioHandle g) Communication side cover h) Instrument i) Tripod TS_144 MS50/TS50/TM50, Operation...
  • Page 43: Setting Up For Remote Control (With The Tcps29/30)

    Step Description Radio to Tripod The GHT43 tripod adapter is used to mount the TCPS29/30 to all Leica Step-by-Step standard tripods, and to optimise the radio transmission performance. Attach the TCPS29/30 to the adapter and then attach the adapter to the tripod leg.
  • Page 44: Fixing The Field Controller To A Holder And Pole

    TS_056 After the field controller is placed onto the mounting plate, ensure that the locking pin is put into the locked position. To lock the locking pin, push the locking pin to the right. TS_054 MS50/TS50/TM50, Operation...
  • Page 45: Connecting To A Personal Computer

    Insert the Leica Viva Series USB card. Run the SetupViva&GR_USB_XX.exe to install the drivers necessary for Leica Viva devices. Depending on the version (32bit or 64bit) of the oper- ating system on your PC, you have to select between the three setup files following: •...
  • Page 46 Allow USB connections inside the Connection Settings window of ActiveSync. For PCs with Windows Vista or Windows 7/Windows 8 operating system: Windows Mobile Device Center starts up automatically. If does not start automatically, start Windows Mobile Device Center. MS50/TS50/TM50, Operation...
  • Page 47 The folders on the TS instrument are displayed under Mobile Devices. The folders of the data storage device can be found in either of the following folders: • Leica Geosystems\SmartWorx Viva • SD Card • USB memory device For PCs with Windows Vista or Windows 7/Windows 8 operating system: ...
  • Page 48: Power Functions

    • Reset Windows CE (resets Windows CE and communication settings to factory defaults) • Reset installed software (resets settings of all installed software) • Reset Windows CE and installed software (resets Windows CE and settings of all installed software) MS50/TS50/TM50, Operation...
  • Page 49: Batteries

    +10°C to +20°C/+50°F to +68°F if possible. • It is normal for the battery to become warm during charging. Using the chargers recommended by Leica Geosystems, it is not possible to charge the battery if the temperature is too high.
  • Page 50: Battery For Smartantenna

    Push the battery downwards so that it locks into position. Insert the cover of the battery compartment into the compartment. Push the slide fastener in the direction of the arrow with the close-lock symbol. MS50/TS50/TM50, Operation...
  • Page 51 Push the battery upwards so that it locks into position. Insert the cover of the battery compartment into the compartment. Push the slide fastener in the direction of the arrow with the close-lock symbol. MS50/TS50/TM50, Operation...
  • Page 52: Working With The Memory Device

    005018_001  The lid opens automatically. Slide the USB stick with the Leica logo facing you firmly into the USB host port until it clicks into position.  Do not force the USB stick into the port. Close the lid by pushing the door down. Push the door on the marked part in the middle of the door.
  • Page 53 Slide the microSD card with the logo facing upwards firmly into the slot until it clicks into position. Insert the SIM/microSD card cover to cover slot. Insert the cover over the battery compartment. Push the slide fastener in the direction of the arrow with the close-lock symbol. MS50/TS50/TM50, Operation...
  • Page 54 Gently press on the top of the card to release it from the slot. Remove the SD card. Insert the cover into battery compartment 1. Push the slide fastener in the direction of the arrow with the close-lock symbol. MS50/TS50/TM50, Operation...
  • Page 55: Led Indicators

    Power is 100% - 20%. Power is 20% - 5%. flashing red Power is low (<5%). The remaining time for which enough power is avail- able depends on the type of survey, the temperature and the age of the battery. MS50/TS50/TM50, Operation...
  • Page 56 5% memory left. SD card is full, no raw data is being logged. fast flashing red no SD card is inserted but GS15 is configured to log raw data. MS50/TS50/TM50, Operation...
  • Page 57 GS15 is in RTK base mode. Data is being passed to the RX/TX interface of the communication device. *1 The battery, which currently powers the GS15 GNSS instrument. *2 Other batteries, which are inserted or connected but are not currently power the GS15 GNSS instrument. MS50/TS50/TM50, Operation...
  • Page 58 Link LED no radio link to field controller. radio link to field controller. Data Transfer LED no data transfer to/from field controller. green or green data transfer to/from field controller. flashing Mode LED data mode. configuration mode. MS50/TS50/TM50, Operation...
  • Page 59: Guidelines For Correct Results

    Refer to "5 Check & Adjust" about checking and adjusting instruments.  When a measurement is triggered while the prism is still moving, distance and angle measurements may not be made for the same position and coordinates may vary. MS50/TS50/TM50, Operation...
  • Page 60 Ensure that the instrument setup is stable, especially if steep sightings are necessary. If an incomplete positioning is indicated check the position deviation and repeat the according positioning command. MS50/TS50/TM50, Operation...
  • Page 61: Check & Adjust

    Check & Adjust Overview Description Leica Geosystems instruments are manufactured, assembled and adjusted to the best possible quality. Quick temperature changes, shock or stress can cause deviations and decrease the instrument accuracy. It is therefore recommended to check and adjust the instrument from time to time.
  • Page 62: Preparation

    Refer to "5.5 Adjusting the Circular Level of the Instru- ment and Tribrach". adjust the laser/optical Refer to "5.7 Inspecting the Laser Plummet of the plummet Instrument". adjust the tripod Refer to "5.8 Servicing the Tripod". MS50/TS50/TM50, Check & Adjust...
  • Page 63: Combined Adjustment (L, T, I, C, Atr And Tele Camera)

    ATR Hz and V adjust- ment errors.  Use a clean Leica standard prism as the target. Do not use a 360° prism. If Calibrate the telescope camera is checked and a telescope camera is available, the adjustment includes the determination of the telescope camera zero point.
  • Page 64 If the Use status is set to Yes, Next overwrites the old adjust- ment errors with the new ones. to be determined Redo rejects all new determined adjustment errors and repeats again the whole procedure. Refer to paragraph "Combined adjust- ment procedure step-by-step". MS50/TS50/TM50, Check & Adjust...
  • Page 65: Tilting Axis Adjustment (A)

    The standard deviation can be calculated from the second run onwards.  Measure at least two runs. Next to continue with the check & adjust procedure. Select Add another calibration loop if more runs have to be added. Next and continue with step 3. MS50/TS50/TM50, Check & Adjust...
  • Page 66: Adjusting The Circular Level Of The Instrument And Tribrach

    Tribrach: If it extends beyond the circle, use the supplied allen key to centre it with the adjustment screws.  After the adjustments, all adjusting screws must have the same tightening tension and no adjusting screw should be loose. MS50/TS50/TM50, Check & Adjust...
  • Page 67: Adjusting The Circular Level Of The Prism Pole

    The laser plummet is located in the vertical axis of the instrument. Under normal condi- tions of use, the laser plummet does not need adjusting. If an adjustment is necessary due to external influences, return the instrument to any Leica Geosystems authorised service workshop.
  • Page 68: Servicing The Tripod

    If the centre of the laser dot describes a perceptible circular movement, or moves more than 3 mm away from the point which was first marked, an adjustment may be required. Inform your nearest Leica Geosystems author- ised service workshop. Depending on brightness and surface, the diameter of the laser dot can vary.
  • Page 69: Care And Transport

    Shipping When transporting the product by rail, air or sea, always use the complete original Leica Geosystems packaging, transport container and cardboard box, or its equivalent, to protect against shock and vibration. Shipping, transport When transporting or shipping batteries, the person responsible for the product must...
  • Page 70: Cleaning And Drying

    Keep plugs clean and dry. Blow away any dirt lodged in the plugs of the connecting cables. Maintenance  An inspection of the product must be done in a Leica Geosystems authorised service workshop. Leica Geosystems recommends an inspection of the product every 12 months. As MS50/TS50/TM50 instruments are equipped with a self-surveillance system...
  • Page 71: Technical Data

    Machine Automation power 2600 1500 5000 2000 7000 prism (MPR122)  For Machine Control purposes only! Shortest measuring distance: 1.5 m For MS50 - R2000: Reflector Range A Range B Range C [ft] [ft] [ft] Standard prism (GPR1, 2200 7300...
  • Page 72 Beam interruptions, severe heat shimmer and moving objects within the beam path can result in deviations of the specified accuracy. Atmospheric conditions type C, range up to 1000 m, GPH1P reflector Target aligned to instrument For MS50 - R2000: std. dev. std. dev. Measurement...
  • Page 73: Distance Measurement Without Reflectors

    Object in shade, sky overcast. Beam interruptions, severe heat shimmer and moving objects within the beam path can result in deviations of the specified accuracy. The display resolution is 0.1 mm. For MS50 - R2000: Standard measuring std. dev. Measure time,...
  • Page 74: Distance Measurement - Long Range (Lo Mode)

    The display resolution is 0.1 mm. Characteristics Principle: Phase measurement Type: Coaxial, visible red laser Carrier wave: 658 nm Measuring system: System analyser basis 100 MHz - 150 MHz MS50/TS50/TM50, Technical Data...
  • Page 75: Automatic Target Aiming Atr

    Shortest measuring distance: 360° prism ATR: 1.5 m ATR accuracy with ATR angle accuracy Hz, V (std. dev. ISO 17123-3, atmospheric conditions type C): the GPR1 prism TS50/TM50, 0.5": 0.5 " (0.15 mgon) MS50/TS50/TM50, 1": 1 " (0.3 mgon) MS50/TS50/TM50, Technical Data...
  • Page 76 GRZ4 1” 0.5” GRZ122 005232_001 Leica GRZ4 prism (360°) Leica GRZ122 prism (360°) Leica circular prisms and Leica circular Mini prisms ATR accuracy [mm] Distance measurement [m] " Instrument angle accuracy ["] Maximum speed in Maximum tangential speed: 9 m/s at 20 m; 45 m/s at 100 m...
  • Page 77: Scanning

    Scanning Availability Available for MS50 R2000 and on CS when connected to MS50 R2000. Range The following ranges refer to optimal measurement conditions (object in shade, sky overcast, static target object). Mode Kodak Grey Card (Albedo 90%) Range, up to...
  • Page 78: Powersearch Ps

    Time to focus: Typical 2 s Focus range: 1.7 m to infinity Image storage: JPEG up to 5 Mpixel (2560 x 1920) Zoom, digital: 4-step (1x, 2x, 4x, 8x) Whitebalance: Automatic and user configurable Brightness: Automatic and user configurable MS50/TS50/TM50, Technical Data...
  • Page 79: Smartstation

    Up to 50 km, assuming reliable data-link is available RTK Data Formats Formats for data reception: Leica proprietary GPS / Glonass and GNSS real-time data formats, CMR, CMR+, RTCM V2.1 / 2.2 / 2.3 / 3.1 / 3.2 MS50/TS50/TM50, Technical Data...
  • Page 80: Smartstation Dimensions

    7.10.2 SmartStation Dimensions SmartStation With GS15 dimensions 196 mm 248 mm 114 mm 114 mm 228 mm 005118_001 With GS14 190 mm 248 mm 114 mm 114 mm 228 mm 005119_001 MS50/TS50/TM50, Technical Data...
  • Page 81 186 mm 248 mm 114 mm 114 mm 228 mm 005120_001 With GS08plus 186 mm 248 mm 114 mm 114 mm 228 mm 005121_001 With RH16/RH17 72 mm 248 mm 114 mm 114 mm 228 mm 005122_001 MS50/TS50/TM50, Technical Data...
  • Page 82: Smartantenna Technical Data

    Galileo E1 1575.42 MHz  Galileo E5a 1176.45 MHz  Galileo E5b 1207.14 MHz  Galileo Alt-BOC 1191.795 MHz Gain (typically) 37 dBi 27 dBi 27 dBi Noise Figure (typically) < 3 dBi < 2 dBi < 2 dBi MS50/TS50/TM50, Technical Data...
  • Page 83 Waterproof to 1 m temporary immersion Tested for 2 hours in 1.40 m depth Humidity Protection Up to 100 % The effects of condensation are to be effectively counteracted by periodically drying out the antenna. MS50/TS50/TM50, Technical Data...
  • Page 84: Conformity To National Regulations

    • FCC Part 15 (applicable in US) national regulations • Hereby, Leica Geosystems AG, declares that the product MS50/TS50/TM50 is in compliance with the essential requirements and other relevant provisions of Direc- tive 1999/5/EC and other applicable European Directives. The declaration of conformity may be consulted at http://www.leica-geosystems.com/ce.
  • Page 85: Radiohandle

    • FCC Part 15 (applicable in US) national regulations • Hereby, Leica Geosystems AG, declares that the RadioHandle is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC and other applicable European Directives. The declaration of conformity may be consulted at http://www.leica-geosystems.com/ce.
  • Page 86: Gs08Plus

    • FCC Part 15, 22 and 24 (applicable in US) national regulations • Hereby, Leica Geosystems AG, declares that the product GS08plus is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC and other applicable European Directives. The declaration of conformity can be consulted at http://www.leica-geosystems.com/ce.
  • Page 87 • FCC Part 15, 22 and 24 (applicable in US) national regulations • Hereby, Leica Geosystems AG, declares that the product GS12 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity can be consulted at http://www.leica- geosystems.com/ce.
  • Page 88 • FCC Part 15 (applicable in US) national regulations • Hereby, Leica Geosystems AG, declares that the product GS14 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC and other applicable European Directives. The declaration of conformity can be consulted at http://www.leica-geosystems.com/ce.
  • Page 89 • FCC Part 15, 22 and 24 (applicable in US) national regulations • Hereby, Leica Geosystems AG, declares that the product GS15 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity can be consulted at http://www.leica- geosystems.com/ce.
  • Page 90: Dangerous Goods Regulations

    Leica Geosystems has developed Guidelines on “How to carry Leica products” and “How to ship Leica products” with Lithium batteries. Before any transpor- tation of a Leica product, we ask you to consult these guidelines on our web page (http://www.leica-geosystems.com/dgr) to ensure that you are in accord- ance with the IATA Dangerous Goods Regulations and that the Leica products can be transported correctly.
  • Page 91: General Technical Data Of The Instrument

    Angle Display: 360°’", 360° decimal, 400 gon, 6400 mil, V % Distance Display: m, ft int, ft us, ft int inch, ft us inch Position: TM50 face I only, TS50/MS50 both faces Touch screen: Toughened film on glass Instrument Ports Name...
  • Page 92 200 gon/s Time for change face: Typically 2.9 s Power External supply voltage: Nominal voltage 12.8 V DC Range 12 V-18 V Standby power consumption: Typically 0.3 W Operating power consumption: Typically 8 W (max. 40 W) MS50/TS50/TM50, Technical Data...
  • Page 93 Environmental Temperature Specifications Type Operating temperature [°C] Storage temperature [°C] All types -20 to +50 -40 to +70 Leica SD cards, all -40 to +80 -40 to +80 sizes Battery internal -20 to +55 -40 to +70 Bluetooth -30 to +60...
  • Page 94: Scale Correction

    For high precision measurements, the relative humidity must be measured and entered along with the air pressure and the temperature. Air humidity correction 100% ppmAir humidity correction [mm/km] Relative humidity [%] 10 20 30 40 50 °C C° Air temperature [°C] TS_104 MS50/TS50/TM50, Technical Data...
  • Page 95 Index n Type Index n Carrier wave [nm] MS50 with R2000 1.0002863 (Wave Form Digitiser) TS50/TM50 with R1000 Combined EDM (Phase Shift / System Analyser) The index n is calculated from the formula of Barrel and Sears, and is valid for: Air pressure p: 1013.25 mbar...
  • Page 96 50°F 50°F 40°F 40°F 30°F 30°F 20°F 20°F 10°F 10°F 0°F 0°F -10°F -10°F -20°F -20°F 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 inch Hg [ ft ] TS_109 MS50/TS50/TM50, Technical Data...
  • Page 97: Reduction Formulas

    (radius of the earth) Earth curvature (1/R) and mean refraction coefficient (k) are automatically taken into account when calculating the horizontal distance and height difference. The calculated horizontal distance relates to the station height and not to the reflector height. MS50/TS50/TM50, Technical Data...
  • Page 98 The standard deviation of the arithmetic mean of the distance can be calculated as follows: Standard deviation of the arithmetic mean of the distance TS_116 s Standard deviation of a single meas- urement n Number of measurements MS50/TS50/TM50, Technical Data...
  • Page 99: Software Licence Agreement

    Leica Geosystems. Such software is protected by copyright and other laws and its use is defined and regulated by the Leica Geosystems Software Licence Agreement, which covers aspects such as, but not limited to, Scope of the Licence, Warranty, Intellectual Property Rights, Limitation of Liability, Exclusion of other Assurances, Governing Law and Place of Jurisdiction.
  • Page 100 805805-3.0.0en Original text Published in Switzerland © 2015 Leica Geosystems AG, Heerbrugg, Switzerland Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Switzerland Phone +41 71 727 31 31 www.leica-geosystems.com...

This manual is also suitable for: