EDM Settings - Enter
Atmospheric Data
Settings
Field
Description
This screen enables the entry of atmospheric parameters. Distance measure-
ment is influenced directly by the atmospheric conditions of the air in which
the measurements are taken. In order to take these influences into considera-
tion distance measurements are corrected using atmospheric correction param-
eters.
The refraction correction is taken into account in the calculation of the height
differences and the horizontal distance. Refer to "16.7 Scale Correction" for the
application of the values entered in this screen.
When PPM=0 is selected, the Leica standard atmosphere of
1013.25mbar, 12°C, and 60% relative humidity is applied.
Description
Working range:
5m to 150m (15ft to 500ft)
Positioning accuracy:
5cm at 100m (1.97" at 330ft)
a
b
6 m
(20 ft)
(20 ft)
TSOX_095
a
Flashing red diode
b
Flashing yellow diode
6 m
55