Distance Measurement Reflector (>4.0Km) - Leica TS03 User Manual

Table of Contents

Advertisement

Accuracy
Characteristics
Laser dot size
16.4
Range
Atmospheric condi-
tions
Accuracy
Technical Data
Standard
ISO17123-4
measuring
0m - 500m
2 mm + 2 ppm
>500m
4 mm + 2 ppm
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy.
Tracking
Standard deviation
measuring*
Tracking
5 mm + 3 ppm
* Accuracy and measure time depend on atmospheric conditions, target object
and observation situation.
Type
Type
Carrier wave
Measuring system
Distance [m]
at 30
at 50
at 100
Distance Measurement Reflector (>4.0km)
R500,
R1000
Standard prism
(GPR1)
Reflector tape
60 mm x 60 mm
Range of measurement:
Display unambiguous:
Range
A
B
C
Measurement
Mode
P-Long (>4.0 km)
Measure time,
typical [s]
3 - 6
3 - 6
Description
Coaxial, visible red laser
658 nm
System Analyzer Basis 100 MHz - 150 MHz
Laser dot size, approximately [mm]
7 x 10
8 x 20
16 x 25
Range A
Range B
[m]
[ft]
[m]
2200
7300
7500
600
2000
1000
From 1000 m up to 12000 m
Up to 12 km
Description
Strong haze, visibility 5km; or strong sunlight, severe
heat shimmer
Light haze, visibility about 20km; or moderate sun-
light, slight heat shimmer
Overcast, no haze, visibility about 40km; no heat
shimmer
ISO17123-4
Measure time,
typical [s]
5 mm + 2 ppm
2.5
Measure time,
maximum [s]
15
15
Measure time, typical [s]
0.25
Range C
[ft]
[m]
[ft]
24600
>10000
>33000
3300
1300
4200
Measure time,
maximum [s]
12
189

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts07

Table of Contents