Table of Contents

Advertisement

5.5
Description
Access

EDM Settings

52
Field
Option
Setout Beep
On
Off
EDM Settings
The settings on this screen define the active EDM, Electronic Distance
Measurement. Different settings for measurements are available with Non-
Prism (NP) and Prism (P) EDM modes.
1.
Select Settings from the Main Menu.
2.
On the General page, select EDM.
3.
Press the
button to scroll through the screens of available set-
tings.
Key
Description
Atmos
To enter atmospheric data ppm.
Ind.PPM
To enter an individual ppm value.
To enter projection scale details.
Scale
To view EDM Signal reflection value.
Signal
To view the EDM frequency.
Freq.
Description of fields
Field
Description
EDM Mode
Prism
Non-Prism
Tape
Description
The instrument beeps when the distance
from the current position to the point to be
staked is ≤ 0.5 m.
The closer the prism is to the point to be
staked the faster the beeps will be.
Beep is deactivated.
Description
For distance measurements using prisms.
For distance measurements without prisms.
For distance measurements using Retro
reflective targets (3 mm + 2 ppm).
Settings