Leica TS03 User Manual page 73

Table of Contents

Advertisement

Setup methods
Apps
N
H
P1
P0
TSOX_033
The following setup methods are available:
Setup method
Orientation with Angle
Orientation with Coordinates
Height Transfer
Resection
Helmert Resection
Local Resection
Each setup method requires different input data and a different number of tar-
get points.
P3
P0 Instrument station
P1 Known point
P2 Known point
P2
E
P3 Known point
Description
The station is known. Aim at a target to set
the orientation.
The station and target coordinates are
known. Aim at a target to set the orientation
and height.
The station is known, a new station height
must be computed. Measure to one or more
known targets to compute new height for
the station.
The station is unknown. Measure to two or
more target points to compute station coor-
dinates and orientation. Scale setting is con-
figurable.
The station is unknown. Measure to two or
more target points to compute station coor-
dinates and orientation. The measured
angles and distances are adjusted, based on
coordinates of a local and global system.
A 2D Helmert transformation is used, with
four (shift x, shift y, rotation and scale) or
three (shift x, shift y, rotation) parameters,
depending on the scale setting in the config-
uration. Points can be defined as 1D, 2D or
3D.
The station is unknown. Measure distances
to two points:
To the origin (E = 0, N = 0, H = 0) of the
coordinate system
To a point the North or East direction of
the coordinate system
Scale and standard deviation are not calcula-
ted.
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts07