Leica TS03 User Manual page 54

Table of Contents

Advertisement

Field
No. of
Meas.
Leica Const.
Abs. Const.
Laser-Point
Guide Light
54
Description
Description
Average
Repeats measurements in standard measur-
ing mode. Define the number of repetitions
in No. of Meas.. The average distance and
the standard deviation for the averaged dis-
tance are calculated.
During the measurement, a status bar, the
calculated slope distance and the standard
deviation are displayed. Use Back to return
to the previous screen without storing the
data. Use Re-meas to omit all previous
measurements and to restart. Use Cont to
cancel the measurement process and to cal-
culate the average from the available meas-
urements.
Tracking
For continuous distance measurements with
prisms (3 mm + 1.5 ppm) or without prisms
(5 mm + 3 ppm).
Prism
For long range distance measurements with
(>4.0km)
prisms (5 mm + 2 ppm).
Editable field
The number of repeated measurements.
Limit value: 2 to 99
Display only
This field displays the Leica prism constant
for the selected Prism Type.
Editable field
Where Prism Type is User 1 or User 2 this
field becomes editable to set a user defined
constant. Input can only be made in mm.
Limit value: -999.9mm to +999.9mm.
Display only
This field displays the absolute prism con-
stant for the selected Prism Type.
Editable field
Where Prism Type is User 1 or User 2 this
field becomes editable to set a user defined
constant. Input can only be made in mm.
Limit value: -999.9mm to +999.9mm.
Off
Visible laser beam is deactivated.
On
Visible laser beam for visualising the target
point is activated.
Off
Guide Light is deactivated.
On
Guide Light is activated. The person at the
prism can be guided by the flashing lights
directly to the line of sight. The light points
are visible up to a distance of 150 meters.
This is useful when staking out points.