Mitsubishi Electric Q12DCCPU-V User Manual page 315

Melsec-q series c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

10
PROGRAMMING USING MELSEC DATA LINK
FUNCTIONS
Device type
Code
DEC.
HEX.
-32735
8021
H
-32734
8022
H
-32732
8024
H
-32669
8063
H
-32668
8064
H
(4) Device types for accessing CC-Link IE Controller Network modules or
Device Type
Code
DEC.
HEX.
1
1
H
2
2
H
23
17
H
24
18
H
Device Type
Code
DEC.
HEX.
5
5
H
14
E
H
25
19
H
28
1C
H
1000
3E8
H
2000
7D0
H
23000
59D8
H
24000
5DC0
H
25000
61A8
H
28000
6D60
H
Table 10.8 Device types for accessing CC-Link module (continued)
*1
Device name
DevRX
Other station RX
DevRY
Other station RY
DevRW
Other station link register
DevSB
Other station SB (link special relay for CC-Link)
DevSW
Other station SW (link special register for CC-Link)
* 1 The device name specification (macro) is defined in this function's include file, "MdFunc.h". (
Page 9-9, Section 9.4)
* 2 The device cannot be used in the mdRandR, mdRandREx, mdRandW, mdRandWEx, mdDevSet,
mdDevSetEx, mdDevRst, or mdDevRstEx functions.
MELSECNET/H modules
In a user program, link device access methods and message send/receive can be
selected by specifying a device.
(a) Internal buffer access
Table 10.9 Device types for internal buffer access
*1
Device name
DevX
Own station link input internal buffer (LX buffer)
DevY
Own station link output internal buffer (LY buffer)
DevB
Own station link relay internal buffer (LB buffer)
DevW
Own station link register internal buffer (LW buffer)
* 1 The device name specification (macro) is defined in this function's include file, "MdFunc.h".
Page 9-9, Section 9.4)
(b) Direct access
Table 10.10 Device types for direct access
*1
Device name
DevSM
Own station direct link special relay (SB)
DevSD
Own station direct link special register (SW)
DevQSB
Own station direct link relay (SB)
DevQSW
Own station direct link register (SW)
DevLX(0)
Own station direct link input (LX)
DevLY(0)
Own station direct link output (LY)
DevLB(0)
Own station direct link relay (LB)
DevLW(0)
Own station direct link register (LW)
DevLSB(0)
Own station direct link special relay (SB)
DevLSW(0)
Own station direct link special register (SW)
* 1 The device name specification (macro) is defined in this function's include file, "MdFunc.h".
Page 9-9, Section 9.4)
* 2 These (DevSM, DevQSB, and DevLSB(0)) are the same device.
* 3 These (DevSD, DevQSW, and DevLSW(0)) are the same device.
* 4 Only for CC-Link IE Controller Network modules, access can be made to areas of LB4000 and
higher and LW4000 and higher.
10.12 Device Types for the MELSEC Data Link Function
Device
*2
*2
Device
Device
*2
*3
*2
*3
*4
*4
*2
*3
9
10
11
12
13
(
A
I
(
10
- 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q06ccpu-vQ06ccpu-v-bSw3pvc-ccpu-e

Table of Contents