C CONTROLLER SETTING UTILITY
(4) Intelligent function module detailed settings screen
Table 4.27 Description of the Intelligent function module detailed settings screen
Item
Slot, Type, Model name
Error time output mode
H/W error time CPU operation mode
I/O response time
Control CPU
End
button
Cancel
button
4
- 40
4.9 I/O Assignment Settings Tab
Detailed settings for I/O modules and intelligent function modules can be set on this
screen.
For setting items on this screen, refer to the C Controller Module User's Manual
(Hardware Design, Function Explanation).
Figure 4.28 Intelligent function module detailed settings screen
Displays the "Slot", "Type", and "Model" set on the I/O assignment screen.
Select the output mode for error detection.
(Default: "Clear")
Select the operation mode of the C Controller module for H/W error detection.
(Default: "Stop")
Set the I/O response time.
Mounted module
High-speed input module, interrupt
module
Input module, I/O combined module
Set the control CPU
In a multiple CPU system, the settings for each CPU module must be identical.
(Default: "No.1")
Saves the settings and closes the Intelligent function module detailed settings
screen.
Closes the Intelligent function module detailed settings screen without saving the
settings.
Description
Default
0.2
10
(In increments of ms)
Reference
page
Page 4-37